100
FIGURE 54
WIRING DIAGRAM FOR NON-COMMUNICATING CONDENSORS AND HEAT-PUMPS WITH COMMUNICATING FURNACE AND THERMOSTAT.
ST-A1194-54-01
Co
m
m
un
ica
tin
g
Fu
rn
ac
e
INTEGRATED FURNACE CONTROL
THERMOSTAT WIRING DIAGRAMS
Figure 53 is the wiring diagram for connecting the furnace
to an approved EcoNet communicating thermostat and ap-
proved EcoNet communicating condenser. The only ap-
proved configuration is to install dedicated wires directly
from the furnace to the thermostat and a separate set of
dedicated wires directly from the furnace to the condenser.
Additional EcoNet devices can be added to the system as
shown in Figure 53. The approved wiring configuration is
the daisy-chain configuration shown in Figure 53. A star
wiring configuration is not approved and should not be
used.
Note: The only approved configuration requires that four
dedicated wires (E1,E 2, R and C) be installed from the
furnace to the condenser.
A2. SPECIAL CONFIGURATION – WIRING OF
NON COMMUNICATING CONDENSORS
AND HEAT-PUMPS WITH COMMUNICATING
FURNACE AND THERMOSTAT (SEE FIG-
URE 54).
Summary of Contents for *96V series
Page 34: ...Field Conversions 34...
Page 35: ...Field Conversions 35...
Page 36: ...36 Field Conversions...
Page 37: ...37 Field Conversions...
Page 38: ...Field Conversions 38...
Page 112: ...112 Diagnostics TABLE 20 continued R96V FAULT CODES WITH DESCRIPTIONS AND SOLUTIONS...
Page 117: ...117 TABLE 20 continued R96V FAULT CODES WITH DESCRIPTIONS AND SOLUTIONS Diagnostics...
Page 123: ...123 FIGURE 62 2 STAGE ECM FURNACE WIRING DIAGRAM Troubleshooting...
Page 124: ...124 CM 1014...