INSTALLATION
34
DIMENSIONS AND TECHNICAL DATA
Model
8A0340N0
Gas Details – Natural Gas
Storage capacity
litres
155
Hourly Gas Consumption
(MJ)
40
Hourly recovery
(natural gas @ 45°C rise)
litres
185
Min. Gas Supply Pressure
(kPa) 1.13
First hour capacity *
litres
340
Burner Test Point Gas Pressure(kPa) 1.00
Mass (tank)
Cartoned
kg
65
Max. Gas Supply Pressure
(kPa) 3.50
Full
kg
215
Main injector orifice (mm)
∅
2.80
Pilot injector number
27
* Based on an inlet water temperature of 15°C.
Letter N is included in the model number, e.g. 8A0340N0, to denote gas type.