Rheem Heating, Cooling and Water Heating
Electrical and Physical Data
Model
Number
13AJM
ELECTRICAL
PHYSICAL
Phase
Frequency (Hz)
Voltage (Volts)
Compressor
Fan Motor
Full Load
Amperes
(FLA)
Minimum
Circuit
Ampacity
Amperes
Fuse or HACR
Circuit Breaker
Outdoor Coil
Refrigerant
Per
Circuit
Oz. [g]
Weight
Rated Load
Amperes
(RLA)
Locked Rotor
Amperes
(LRA)
Minimum
Amperes
Maximum
Amperes
Face Area
Sq. Ft. [m2]
No.
Rows
CFM [L/s]
Net
Lbs. [kg]
Shipping
Lbs. [kg]
Rev. 6/30/2010
18
1-60-208/230
9/9
48
0.6
12/12
15/15
20/20
8.43 [0.78]
1
1675 [790] 75.2
0
[2132] 120 [54.4] 128 [58.1]
24
1-60-208/230
13.5/13.5
58.3
0.6
18/18
25/25
30/30
8.43 [0.78]
1
1665 [786] 73.8
0
[2092] 121 [54.9] 129 [58.5]
30
1-60-208/230
12.8/12.8
73
0.6
17/17
20/20
25/25
10.29 [0.96]
1
2075 [979] 86.08 [2440] 139 [63.1] 147 [66.7]
36
1-60-208/230
16.7/16.7
79
0.8
22/22
30/30
35/35
12.43 [1.15]
1
2690 [1269] 96
.00
[2722] 159 [72.1] 167 [75.8]
42
1-60-208/230
17.9/17.9
112
0.8
24/24
30/30
40/40
16.39 [1.52]
1
2980 [1406] 126.4 [3583] 188 [85.3] 192 [87.1]
48
1-60-208/230
21.8/21.8
117
0.8
29/29
35/35
45/45
21.85 [2.03]
1
3175 [1498] 144
.0
[4082] 207 [93.9] 218 [98.9]
60
1-60-208/230
26.4/26.4
134
1.2
35/35
45/45
60/60
21.85 [2.03]
1
3570 [1685] 176
.0
[4990] 223[101.2] 234 [106.1]
NOTE: Factory Refrigerant Charge includes refrigerant for 15 feet of standard line set.
Unit Dimensions
Model No.
13AJM
Unit Dimensions
48, 60
31
5
/
8
[803]
31
5
/
8
[803]
Width “W”
Inches
Length “L”
Inches
Height “H”
Inches
18, 24
23
5
/
8
[600]
23
5
/
8
[600]
24
1
/
4
[616]
30
27
5
/
8
[702]
27
5
/
8
[702]
24
1
/
4
[616]
36, 42
31
5
/
8
[803]
31
5
/
8
[803]
27
15
/
16
[710]
35
15
/
16
[913]
[ ] Designates Metric Conversions
L
H
SEE DETAIL A
w