background image

 

 

SAFETY INFORMATION  

 

WARNING: 
BEFORE USING THE TOOL, READ CAREFULLY AND UNDERSTAND

 

THE 

FOLLOWING SAFETY INSTRUCTIONS.FAILURE TO FOLLOW

 

WARNING 

COULD RESULT IN DEATH OR SERIOUS INJURY.

  

 

1. WEAR SAFETY GLASSES OR GOGGLES.

  

Danger to the eyes always exists due to the possibility of dust being blown

 

up by the 

exhausted air or of a fastener flying up due to the improper

 

handling of the tool. For 

these reasons, safety glasses or goggles shall

 

always be worn when operating the 

tool. The employer and/or user must

 

ensure that proper eye protection is worn. The employer 

is responsible to enforce the use of eye protection equipment

 

by the tool operator and all other 

personnel in the work area.

 

NOTE: Non-side shielded spectacles and face shields alone do not 

provide

 

adequate protection. 

 

2. EAR PROTECTION MAY BE REQUIRED IN SOME ENVIRONMENTS. 

As the working condition may include exposure to high noise levels which can

 

lead 

to hearing damage, the employer and user should ensure that any

 

necessary 

hearing protection is provided and used by the operator and others

 

in the work area. 

 

3. DO NOT USE ANY POWER SOURCE EXCEPT AN AIR COMPRESSOR. 

The tool is designed to operate on compressed air. Do not operate the tool on

 

any 

other high pressure gas, combustible gases (e.g. Oxygen, acetylene, etc.)

 

since 

there is the danger of an explosion. For this reason, absolutely so not

 

use anything 

other than an air compressor to operate the tool. 

 

4. OPERATE WITHIN THE PROPER AIR PRESSURE RANGE. 

The tool is designed to operate within an air pressure range of 70 psi 
to100 psi (5 to 7 bar). The pressure should be adjusted to the type of the 
work being fastened. The tool shall never be operated when the operating 
pressure exceeds 120 psi. (8.3 bar). 

 

5. DO NOT OPERATE THE TOOL NEAR A FLAMMABLE SUBSTANCE. 

Never operate the tool near a flammable substance (e.g., thinner, gasoline, etc.). 
Volatile fumes from these substances could be drawn into the compressor and 
compressed together with the air and this could result in an explosion. 

 
 
 

Summary of Contents for CN565X

Page 1: ...ly understand the instructions in this manual before operating the pneumatic power tool Carefully read through this OPERATOR S MANUAL to ensure efficient safe operation It is recommended that the Manu...

Page 2: ...ailers are caused by the failure to observe basic safety rules or precautions An accident can often be avoided by recognizing a potentially hazardous situation before it occurs and by observing approp...

Page 3: ...essional training or experience have sufficient expertise in the field of fastener driving tools and sufficient familiarity with relevant governmental industrial protection provisions accident prevent...

Page 4: ...vels which can lead to hearing damage the employer and user should ensure that any necessary hearing protection is provided and used by the operator and others in the work area 3 DO NOT USE ANY POWER...

Page 5: ...henever the air supply is connected to the tool never touch the trigger unless you intend to drive a fastener into the work It is dangerous to walk around carrying the tool with the trigger pulled and...

Page 6: ...may result Do not interfere with the proper operation of the contact trip mechanism 18 WHEN USING THE TOOL OUTSIDE OR ELEVATED PLACE When fastening roofs or similar slanted surface start fastening at...

Page 7: ...00 nails plastic sheet collated nails Maximum allowable pressure 8 3 bar 120psi Recommended pressure range 5 bar to 7 bar 70psi to 100psi Fasteners Only the nail sizes shown in the table below can be...

Page 8: ...ply compressed air to this nailer Moisture or oil in the air compressor may accelerate wear and corrosion in the nailer Drain daily Connections 1 Fittings Install a female coupler to the hose The fema...

Page 9: ...wood are factors in determining what the pressure should be set at Do not exceed this recommended operating pressure NOTE Dirt and water in the air supply are major causes of wear in the tool An air f...

Page 10: ...itting the hands or body by mistake Nail loading 1 Disconnect the air hose 2 Press LATCH 210270 to open DOOR 210250 then open MAGAZINE COVER 420530 3 Adjust the height of NAIL SUPPORT 420210 according...

Page 11: ...the nailer rail with nailer lubricant Clearing a jam Remove a jammed nail in the following order 1 DISCONNECT AIR HOSE 2 Remove all nails 3 Remove the jammed nail with a slotted head screwdriver 4 In...

Page 12: ...20390 FEED SPRING 26 410250 BUMPER 81 320800 STEP PIN 27 212180 BODY 82 420640 PIN CAP 28 410460 HANDLE GRIP 83 210250 DOOR 29 630110 SNAP RING 32 84 210240 CHECK PAWL B 30 420540 FILTER 85 620070 CHE...

Page 13: ...13 TOOL SCHEMATIC CN565X...

Page 14: ...14 IMPORTER NOBE ApS Bj dstrupvej 10 DK 8410 R nde Denmark Tel 45 8615 1913 E Mail info nobe dk www nobe dk www rgneurope com Construction Coil Nailer CN565X 2021...

Reviews: