Address
:
S603-604 Weiye Building Torch Hi-Tech Industrial Development Zone Xiamen, Fujian Province, P.R.C
Tel: 00865925771197 Fax: 00865925788216
Email: [email protected] http://www.rgblink.cn
43
6. Select <Port 1>, <Port 2>, <Port 3>, <Port 4>, and set the Wall Size W/H and Panel Pixel W/H. For example, set
Wall Size W and Wall Size H as 1, Panel Pixel W as 128 and Panel Pixel H as 256, shown as follows.
7. Turn the rotary knob, and select <Connection Type> for <Port 1>, <Port 2>, <Port 3>, <Port 4>, push the knob
to confirm. G3 NET 2K support 8 kinds of connection type, including
,
,
,
,
,
,
and
. For example:
8. Turn the rotary knob, and select <Offset Settings>, push the knob to confirm, turn the rotary knob, and set
Port 1/2 Offset X, Port 1/2 Offset Y, Port 3/4 Offset X as 0, and set Port 3/4 Offset Y as 256, shown as follows:
9. Turn the rotary knob, and select <Position Settings>, push the knob to confirm, turn the rotary knob, and set
Port 1 X Position and Port 1 Y Position as 0, set Port 2 X Position as 128, Port 2 Y Position as 0, set Port 3 X
Position and Port 3 Y Position as 0, set Port 4 X Position as 128, Port 4 Y Position as 0, shown as follows:
->Port 1/2 Offset X
0
Port 1/2 Offset Y
0
Port 3/4 Offset X
0
Port 3/4 Offset Y
256
Regular
>>
->Unregular
>>
Set Width
>>
Offset Settings
>>
Port 1
->Wall Size W*H: 1*1
Panel Pixel W*H: 1*1
Connection Type
Port 1
->Wall Size W*H: 1*1
Panel Pixel W*H: 128*256
Connection Type
Port 1
Wall Size W*H: 1*1
Panel Pixel W*H: 128*256
->Connection Type
e