background image

Q16pro

User Manual

33

Mode

Each mode is marked in different color and provided
with fitted templates. Users can do operations like splice
under Presentation Mode.

Q16pro

Presentation Mode and Matric Mode

optional.

Matrix Mode:

No need of recreating a container after

changing resolution.

Presentation Mode:

No container is reserved after

change of resolution. Need of recreating a container.

Summary of Contents for 710-1004-01-0

Page 1: ...Q16pro User Manual 1 Q16pro 2022 User Manual Article NO RGB RD UM Q16pro 2022 E000 Version NO V1 0...

Page 2: ...in Power 17 2 2 Connect Signal Source and Control Computer 17 2 3 Turn on Your Product 18 Chapter 3 Use Your Product 19 3 1 XPOSE 2 0 Installation 19 3 2 XPOSE Operation 22 3 2 1 Login in XPOSE 22 3...

Page 3: ...ems and software on the date of commissioning at latest 30 days after the transfer of risks In the event of justified notice of compliant RGBlink can repair the fault or provide a replacement at its o...

Page 4: ...product input or output terminals A protective ground connection by way of the grounding conductor in the power cord is essential for safe operation Use the Proper Power Cord Use only the power cord a...

Page 5: ...ontact your sales representative Once you have removed all the components from their packaging and checked that all the listed components are present visually inspect the system to ensure there was no...

Page 6: ...applications including corporate and visual messaging as well in retail and digital signage applications The Q16pro models allow connection of 4K video sources as well as output to 4K with outputs of...

Page 7: ...u After powered on the LCD touch screen will show LOGO and then enter the main menu Main Menu include Device Settings Load Upgrade English and Version 1 LCD Touch Screen 2 USB Port for device upgrade...

Page 8: ...he LCD screen will show the rear panel of Q16pro Green indicates there is a signal for interface Grey indicates no signal for interface 1 3 1 2 Settings Click Settings to enter the page which includes...

Page 9: ...ateway Then click Save on the right corner to save parameters Serial Communication COM Port default COM port If connected it will show Connection Baud Rate default data 115200 Data Bits 8 Stop Bits 1...

Page 10: ...actory Reset to enter the interface In this interface you can choose to Reset IP or Reset EDID You can also choose to Reset both EDID and IP if necessary After clicking Confirm the LCD screen will pro...

Page 11: ...nk When the user selects the desired bank the interface will pop up Do you want to Load Bank X shown as below Click Confirm to do the selection 1 3 1 4 Upgrade Click Upgrade to enter the interface for...

Page 12: ...pgrade If the user selects Confirm the interface will start upgrading and show the progress bar After upgrade is completed the interface will pop up a prompt to restart the device Click Confirm to res...

Page 13: ...in this interface 1 4 Rear Panel 1 Purple Input 1 3 Input slots 1 3 supporting HDMI DP and other optional modules 2 Blue Output 1 2 Output slots 1 2 supporting HDMI DP and other optional output module...

Page 14: ...g HDMI DVI SDI DP and other optional output modules supporting input modules 3 Yellow COMM Communication board with LAN and RS232 port to connect router or computer to realize software control 4 Power...

Page 15: ...Q16pro User Manual 15 1 5 Demension Dimension of Q16pro 2 483 4mm x 377mm x 89mm Q16pro 2...

Page 16: ...Q16pro User Manual 16 Dimension of Q16pro 4 483 4mm x 446mm x 178mm Q16pro 4...

Page 17: ...to control the device Method 2 Router Connection Connect control computer and Q16pro 4 with Router as shown in the figure above It supports simultaneous online operation by multiple users Connect powe...

Page 18: ...Q16pro User Manual 18 2 3 Turn on Your Product After connection slightly press the power button in the front panel to turn on Q16pro...

Page 19: ...y normally if the resolution is lower than 1920 1080 Operating system Windows 7 or above full version not Ghost version or compact version CPU i5 and above Mac Monitor Resolution must be 1680 1050 pix...

Page 20: ...User Manual 20 2 Click Next to install 3 Click Browse to select the XPOSE software install location Click Install 4 During installation it will pop up the window of Install Shield Wizard for Virtual C...

Page 21: ...Q16pro User Manual 21 5 click Next 6 Then click Install as shown in the figure 7 Click Finish and complete the installation as shown in the figure below...

Page 22: ...ck Register and fill in the blank with first name last name email company and country and then click Register Now Please note that the email shall be invalid and complete otherwise Registration Activa...

Page 23: ...k Start Now If exact Name and Password are needed users can set up them in Authorization Setting under System Setting After login users can find the management including Topology Diagram Search Displa...

Page 24: ...s blank default in Find Device Users are supposed to choose the device needed in System Setting Keyboard Management click keyboard it will redirected to keyboard setting window Keyboard setting is des...

Page 25: ...ear some keys the keys need to selected before hand Clear all is to remove all already set short cut keys Users can also save the keyboard setting as script Click Return to back to system setting Prom...

Page 26: ...word already built Delete Delete user name and password already built Permission functions on this XPOSE 2 0 on this computer that the users are allowed to operate Click the green block to remove the...

Page 27: ...synchronized to other devices For example there is another devices linked to the same network one with IP IP192 168 0 45 1 Set device numbers 2 Select the IP of the device in the drop down menu for D...

Page 28: ...n the All Devices list 2 click in the Chosen Device Click any output port the board where the port locates is selected Users can do settings to the port now A red rectangle flashes around the chosen p...

Page 29: ...port croping for position height and width EDID Input Port chosen port Basic Parameters EDID Template RGB DVI or RGB HDMI Monitor Name type the monitor name Width Height Frequency type in custom param...

Page 30: ...heck current temperature and MAC information IP Support auto manual setting Show IP Address Netmask Gateway Output Module Info users can check current output module name and MCU version Input Module I...

Page 31: ...ous EDID parameter Save IP No change of IP after reset Fan Control Support auto manual setting Fan Speed 0 100 Notice To avoid insufficient heat dissipation the recommended manual fan speed is not les...

Page 32: ...t of output Drag a template to create a container in other word a display area Resolution Users can choose output resolution as shown in the figure Display System is for users to set layout of outputs...

Page 33: ...emplates Users can do operations like splice under Presentation Mode Q16pro Presentation Mode and Matric Mode optional Matrix Mode No need of recreating a container after changing resolution Presentat...

Page 34: ...d 3 columns and each display has a width of 1920 and a height of 1080 the total width will be 5760 and the total height will be 2160 Container Adjustment 1 Move Drag the boarder of the display area to...

Page 35: ...it to the display of the set container Replacement Drag and drop the output into the corresponding Display The output being replaced will turns from gray to white in the list Q16pro allows users to e...

Page 36: ...rea Signal list showing all input signals and resolutions currently Drag the signal to the display click users can rename the input signal and then click to confirm Layer number Numbers in the corner...

Page 37: ...on this icon means data not related width and height need to be filled respectively Layer Adjustment there are two ways to adjust layer 1 Use the bar under the interface Choose one layer and the bar s...

Page 38: ...ttom Copy Selected Delete Selected Layer Set to crop the layer lock the layer to prevent misoperations max to cover up the monitor cover up all monitors in the same screen group with the one signal La...

Page 39: ...tags if necessary Preset Management is designed to switch bank scene setting done in last step Preset Management Mode 1 Manual Mode 2 Schedule Mode The chosen scene will be displayed in the main inte...

Page 40: ...name a Preset Bank Click the color block after Color Selection and choose a new color for the boarder of chosen bank This mode is designed to set auto bank scene preset switch Steps are as follows 1 C...

Page 41: ...Module 790 1004 02 0 HDMI2 0 DP1 2 4K 60 Input Module 790 1004 03 0 Quad DVI Input Module 790 1004 04 0 Quad 3G SDI Input Module 790 1004 21 0 PVW Module 790 1004 22 0 Quad HDMI 1 3 Output Module 790...

Page 42: ...Q16pro User Manual 42 Chapter 5 Support 5 1 Contact Us...

Page 43: ...hat handles digital video signals only and one with 29 pins that handles both digital and analog video SDI Serial Digital Interface Standard definition video is carried on this 270 Mbps data transfer...

Page 44: ...primarily for video but also for audio USB and other data DisplayPort orDP is backwards compatible with HDMI DVI and VGA DP 1 1 Was ratified on 2 April 2007 and version 1 1a was ratified on 11 January...

Page 45: ...screw type connector with a 2 5mm ferrule FC is a round shaped threaded fiber optic connector mostly used on Datacom telecom measurement equipment single mode laser ST Straight Tip was invented by AT...

Page 46: ...e Cat6 cabling infrastructure ST2110 A SMPTE developed standard ST2110 describes how to send digital video over and IP networks Video is transmitteduncompressedwithaudio and other data in a separate s...

Page 47: ...s Built on the DMX512 data format ArtNet enables multiple universes of DMX512 to be transmitted using ethernet networks for transport MIDI MIDI is the abbreviation of Musical Instrument Digital Interf...

Page 48: ...nly used colour bars are eight full field bars On computer monitors the most commonly used colour bars are two rows of reversed colour bars Seamless Switching A feature found on many video switchers T...

Page 49: ...sion History The table below lists the changes to the User Manual Format Time ECO Description Principal V1 0 2022 05 30 0000 Release Aster All information herein is Xiamen RGBlink Science Technology C...

Reviews: