R F S T h e C l e a r C h o i c e
®
Recommended
Installation Instructions
Please visit us on the internet at http://www.rfsworld.com
Radio Frequency Systems
Installation Instructions
603100638500 Rev 1
Wideband Diplexer
In-line Diplexer 698-960 MHz/1710-2200 MHz
FD9R6004 Series
The torque wrench must be perpendicular to the
diplexer connector flange and jumper cable
connector swivel when tightening.
Note:
No angular torque from the jumper cable is
allowed at any time. Fluctuation between diplexer
and jumper axes < ± 2.5°.
See Figure 4
.
JUMPER
90°
> 200 mm (8 in)
before jumper
bending
A
D
I
P
L
E
X
E
R
J
U
M
P
E
R
DIPLEXER
Connector Axis
Torque Wrench
25 Nm (18.4 ft-lbs)
D
I
P
L
E
X
E
R
J
U
M
P
E
R
Fluctuation allowed
between diplexer and
axes: < ± 2.5°
Not Allowed > ± 2.5°
Allowed < ± 2.5°
JUMPER CONNECTION DETAIL
Figure 4
H
DRAWINGS
CL
82.1 (3.23)
3x35.5 (1.40)
61.2 (2.41)
37.6 (1.48)
44.5 (1.75)
90 (3.54)
153.9 (6.06)
21.4 (0.84)
147.1 (5.79)
35.5 (1.40)
60.2 (2.37)
120.4 (4.74)
218.1 (8.59)
164.1 (6.46)
70.3 (2.77)
70.3 (2.77)
110.0 (4.33)
40.0 (1.57)
FRONT VIEW
SIDE VIEW
TOP VIEW
POLE MOUNT
CONFIGURATION
WALL MOUNT
CONFIGURATION
Dimensions shown in mm (in)
Breathable