13.13 Inconsistent Heatless Dryer Cycling
Possible Cause
Check
Corrective Action
Defective Solenoid
Valve
Measure voltage going
to the Heatless Dryer
Solenoid Valves
(section 9.9 )
If correct VDC
IS
present, replace
Solenoid Valves
included in the 8,000
Hour Maintenance Kit
(section 11.6 )
Defective Cycle Timer
Measure voltage going
to the Heatless Dryer
Solenoid Valves
(section 9.9 )
If correct VDC
IS NOT
present, replace the
Cycle Timer
(section 11.4 )
13.14 Compressor Doesn’t Operate
Possible Cause
Check
Corrective Action
Defective Compressor
Measure voltage to
Compressor
(section 9.3 )
If voltage is good,
replace Compressor
(section 11.5 )
or send it in for repair
(section 12. )
No power to
Compressor
Measure voltage to
Compressor
(section 9.3 )
If voltage is not present
or fluctuates, continue
to next Possible Cause
Defective Solid State
Relay
Measure voltages at
Solid State Relay
(section 9.6 )
If measurements are
bad, replace Solid State
Relay (section 11.1 )
System is in
SHUTDOWN
state
On the Display Panel,
verify that the system is
in
SHUTDOWN
state
Press the
RESET
Button
13.15 Compressor Won’t Build Pressure
Possible Cause
Check
Corrective Action
Low System Pressure
Verify System Pressure
(section 8.14 )
Adjust System Pressure
to 50 PSI/345
KPa(section 8.14 )
Defective Unloader
Valve
Test Unloader Valve
operation (section 9.8 )
Replace Unloader
Valve
(section 11.4 )
Leak in air system
Check all hoses and
fittings between
Compressor and Air
Tank for air leaks
(section 9.17 )
Connect, tighten, or
replace leaking
component