DNT90 Integration Guide - 05/10/12
Figure 8.6.1.9
Figure 8.6.1.9 shows the second
I/O Setup
tab contents, corresponding to Bank 6 ADC input and DAC
output parameters. The ADC and DAC reference voltages, the ADC sampling interval, the high and low
ADC thresholds for event reporting and event reporting triggers on each ADC channel can be set, along
with the initial output values for each DAC channel. The event reporting I/O predelay and alternate GPIO
functions can also be set from this tab.
The DNT90 Demo Utility
File
,
Options
and
Help
menus are shown in Figure 8.7.8.
Figure 8.7.8