08 June 2009

 

 

6.  X.21 Aggregate Port 

 
The X.21 port is a DB15 male connector; this is connected internally to a header on 
the PCB using a ribbon cable. The X.21 port may be configured as DTE or DCE by 
fitting the ribbon cable to the appropriate X.21 Port Header, and by selecting settings 
on DIP switch 5. 

Note:

 

DTE is the standard configuration, and is used in all 

applications where the network provides the signal timing.

 

 
Transceivers are specified to ± 15kV IEC1000-4-2 air discharge ESD protection and 
port connections are additionally protected by Tranzorb type arrays. 
 
This port carries an aggregate of three bi-directional data channels; one X.21 
channel and two V.24 channels.  
 
 

 

 
 

Standard X.21 Port Pin-out (when in DTE configuration) – D15M on chassis 

Circuit 

Pin A

Pin B 

Direction

Notes 

T Transmit 

Data 

9  Output   

R Receive 

Data 

11  Input 

 

C Control 

10  Output  Permanently 

on 

I Indication 

12  Input 

Signal 

ignored 

Signal Element 
Timing 

13 

Input 

Timing signal derived from 
the network 

G Ground 

15   

 

X Signal 

Element 

Timing 

14 

Output 

Timing signal transmitted to 
network (X). Special applications 
only. Requires to be enabled 
using mode DTE + Timing X 

 

enabled 

 

Screen / Drain 

 

 

 

Must be earthed to shell 

 

X.21 (DTE) 

 

X.21 (DCE) 

 

X.21 

V24 

X.21 header locations 

Headers connected 

to X.21 Port 

Standard header location 

DCE header location only 

used when SMX3/40 

provides signal timing 

Summary of Contents for 21 Sub-MUX

Page 1: ...s plc U U Ut t ti i il l li i it t ty y y N N Ne e et t tw w wo o or r rk k k S S Sp p pe e ec c ci i ia a al l li i is s st t ts s s SMX3 21 Sub MUX X 21 V 24 Dual Protocol sub rate multiplexer User...

Page 2: ...rt 8 8 X 21 Data Port Channel A 10 9 V 24 Data Ports Channels B C 11 10 DIP Switches 13 11 LEDs 18 12 Power Input 19 13 Alarms 19 14 Example Configurations 20 15 Blank Setting Table 22 Issue Comments...

Page 3: ...with reversible mounting brackets permitting either the connectors or the LEDs to face the front of the rack SMX3 21 aggregates one X 21 data channel Channel A and two V 24 data channels Channel B Ch...

Page 4: ...Channel B is re transmitted onto a second point to point link at the aggregate level via the Concatenation Port For this to operate all links must be synchronised to the network master timing signal I...

Page 5: ...ame regardless of aggregate speed Data Channel Aggregate Speed 64kbit s 128kbit s 192kbit s 256kbit s Channel A X 21 Bandwidth kbit s 64 64 or 128 Sample Rate 16k 32k 48k 64k Baud Rate range Async Mod...

Page 6: ...arrays This port carries an aggregate of three bi directional data channels one X 21 channel and two V 24 channels Standard X 21 Port Pin out when in DTE configuration D15M on chassis Circuit Pin A P...

Page 7: ...erived from within the unit in this case the Clock Source must be configured to Master In both cases the timing signal is output on pins 6 and 13 Optional X 21 Port Pin out when in DCE configuration D...

Page 8: ...ection and port connections are additionally protected by Tranzorb type arrays Aggregate Concatenation Aggregate Concatenation is the interconnection at aggregate level of two co located SMX3 21 units...

Page 9: ...on to a co located SMX3 21 requires a five twisted pair cross over cable with overall shield eg RS 111 8988 Maximum recommended length 10m check Utility standards Aggregate Concatenation Cable D15M D1...

Page 10: ...Transceivers are specified to 15kV IEC1000 4 2 air discharge ESD protection and port connections are additionally protected by Tranzorb type arrays Data received at the Channel A port is always termin...

Page 11: ...switches provide configure options for each port see section 10 V 24 Port Sharing There are two methods by which multiple V 24 ports can be assigned to an aggregate channel Channels ports B and C wit...

Page 12: ...sm DTR is ignored and can be left unconnected the sub multiplexer assumes a continuous ON state DSR is ON when the Aggregate is working an in synchronism RI is unconnected or permanently OFF When RTS...

Page 13: ...hes DIP Switch Locations Dip Switch functions SW1 SW2 SW3 SW4 SW5 SW6 Channel A X 21 Data configuration Channel B V 24 Data configuration Channel C V 24 Data configuration Not used Aggregate Concatena...

Page 14: ...to Off When set to On data transmitted into of the MUX TxD is looped back to its RxD output Channel A requires the clock to be present as this is a DCE port the clock is sourced from the MUX provided...

Page 15: ...lso be used for applications where asynchronous character formats are not specifically supported The baud rate settings are ignored See section 5 Async 8 bit is selected for 7 data bits plus 1 parity...

Page 16: ...here network timing is unavailable The timing signal X is output on pins 6 and 13 Sa and Sb Timing must be selected Enabled as Concat ie DTE Timing X This is the normal setting for the Concatenation P...

Page 17: ...the concatenation port from the co located unit When used in conjunction with the modes Enabled as DCE or Enabled as DTE Signal Timing X the timing signal received from the concatenation port will be...

Page 18: ...able Note For units connected in a concatenated network data on aggregate channels 2 and 3 is broadcast to all configured V 24 ports regardless of whether there is equipment connected to those ports I...

Page 19: ...ther Main Earth 13 Alarms Two alarm relays are incorporated energised when healthy Each relay provides a single changeover contact presented on a plug in terminal strip see equipment layout For a cont...

Page 20: ...ck signal is provided by the X 21 links V 24 channels configured in Transparent mode DIP Switch Settings for both units 8 7 6 5 4 3 2 1 SW1 0 0 0 0 0 0 0 1 SW2 0 0 0 0 0 1 0 0 SW3 0 0 0 0 0 1 0 1 SW4...

Page 21: ...igured in Transparent mode DIP Switch Settings for A1 C1 8 7 6 5 4 3 2 1 SW1 0 0 0 0 0 0 0 1 SW2 0 0 0 0 0 1 0 0 SW3 0 0 0 0 0 1 0 1 SW4 Not used SW5 0 0 0 0 0 0 0 1 SW6 0 1 0 0 0 0 0 0 DIP Switch Set...

Page 22: ...able Location Reference DIP Switch Settings 8 7 6 5 4 3 2 1 SW1 SW2 SW3 SW4 SW5 SW6 2009 RFL Communications plc Connect 17 Avon Way Langley park CHIPPENHAM Wilts SN15 1GG www rflcomms co uk Installati...

Reviews: