background image

DC Power Output

6

INSTALLATION

Installation should only be conducted and/or closely supervised by appropriately qualified

person.

Mounting Options

The unit is supplied with 4 rubber feet for bench use. However, a number of mounting options

have been provided to suit various installations. Mounting options have been provided

underneath of unit in the form of M3 x 0.5 mm threads. The unit can be mounted horizontal or

vertical to suit all types of installations.
The maximum thread length for these screws is 4 mm from the outside edge of the power

supply. Hazardous Voltages exist within the power supply so it is important that the screw

lengths are adhered to.

Connectors

Input Mains: IEC320

Alarm Temperature sensor

1 2 3 4 5 6

Connector Style

6 Way Combicon type with screw terminal plug

Header: Phoenix MC1 ,5/6-G-3,81 (or MCV1 ,5/6-G-3,81 ) or compatible

Plug : Phoenix MC1 ,5/6-ST-3,81 or compatible

3

4

2

1

Connector Style

4 Way Combicon type with screw terminal plug

Header: Phoenix PC4/4-G-7.62 or compatible

Plug : Phoenix PCD4/4-ST-7.62 or compatible

Summary of Contents for SME240-1 2-20

Page 1: ...SME240 12 20 Owner s Manual...

Page 2: ...unting 5 Installation 6 Mounting Options 6 Connectors 6 Alarm Temperature Sensor 6 DC Power Output 6 Connection 7 Cabling 7 Voltage Setting 7 Cooling 8 Specifications 8 Approvals 9 Copyright RFI 2011...

Page 3: ...nnector Flexible mounting options Full protection for the power supply load and battery Local technical support 1 Safety Correct installation is the most critical factor in ensuring the safe use of th...

Page 4: ...very from short circuit is provided with no current tailing in short circuit operation Over voltage protection provides shutdown of power supply Inrush Surge limiting at turn on OTP over temperature p...

Page 5: ...Other fault conditions Battery Charging Operational requirements Trickle Charge When mains is present but the battery voltage is below the LVD Connect voltage the battery is trickle charged circuit th...

Page 6: ...onnected backwards The battery circuit breaker has tripped The relay contacts are rated for 200 mA 60 Vdc Led Indicator Note The Battery Output is derived directly from the Load output Its loading req...

Page 7: ...sure includes 4 x M3 threaded inserts on the bottom surface to allow the unit do be screwed to a mounting bracket Centres are located at 186 5mm x 63mm spacing Feet The SME240 12 20 has 4 x feet posit...

Page 8: ...to suit all types of installations The maximum thread length for these screws is 4 mm from the outside edge of the power supply Hazardous Voltages exist within the power supply so it is important tha...

Page 9: ...DC load cables must be sized to carry the maximum full load current and not exceed the system volt drop requirements Connection The requirements for wiring a SME240 12 20 into a system are as follows...

Page 10: ...pply has inbuilt thermal cooling to maximuse fan life Please ensure that there is no restriction to the venting of the unit Approval Marking Status ACMA C Tick Yes NSW Fair Trading Approval Number U20...