PA516 Series User’s Manual
Asia Pacific | EMEA | Americas
17
SET SHUTDOWN RETRY
Purpose:
Sets the delay before retrying the Reverse Power shutdown cycle.
Syntax:
set shutdown retry <minutes>
Example: Type:
SET SHUTDOWN RETRY 10
Response:
> Shutdown retry delay = 10 Min.
Comment
When an excessive Reverse Power level is detected (currently >35 dBm) the PA is shut down.
The reverse power level is then re-checked 3 times at 10 Second intervals. If the fault condition
persists this retry cycle is repeated once more after the delay specified with this command. If this
fails to clear the fault condition the PA is permanently shut down until either the power is cycled, or
an external Reverse Power Reset signal is applied.
The Minimum value is 0, which disables the feature, and the maximum value is 60 Min.
SET VSWR
Purpose:
Sets the VSWR alarm level.
Syntax:
set vswr <1.00...20.00>
Example:
Type:
SET VSWR 2.5
Response:
> VSWR alarm level = 2.50:1
Comment
When a VSWR level above this configured value is detected, the VSWR alarm is activated.
There is a hysteresis of 0.1 on this alarm. For example if the alarm activates on a VSWR of 1.90:1,
it will remain active until the VSWR drops below 1.80:1.
SHOW ID
Purpose:
Displays the Name, ID, Firmware Version and Serial number.
Syntax:
show id
Example:
Type:
SHOW ID
Response:
SITE-1234A, PA516A, V1.6, Serial No.05080001
>
SHOW SHUTDOWN RETRY
Purpose:
Displays the delay before retrying the reverse power (VSWR) shutdown cycle.
Syntax:
show shutdown retry
Example:
Type:
SHOW SHUTDOWN RETRY
Response:
> Shutdown retry delay = 10 Min
Comment
See the command SHUTDOWN RETRY for more details.