PA516 Series User’s Manual
Asia Pacific | EMEA | Americas
15
HELP
Purpose:
Displays a brief summary of the available commands.
Syntax:
help
The system responds by displaying help screens.
RESET REVPWR
Purpose:
Resets the Reverse Power shutdown.
Syntax:
reset revpwr
Example:
Type:
RESET REVPWR
Response:
>
SET BAUD
Purpose:
Sets the serial interface baud rate.
Syntax:
set baud {1200 | 2400 | 4800 | 9600 | 19200}
Example:
Type:
SET BAUD 19200
Response:
The new serial baud rate will be activated now.
Press any key to continue
Comment
After a key is pressed, the new data rate will be active, so the terminal data rate should be
changed either immediately prior to pressing the key, or immediately after.
The default data rate out of the factory is 9600 baud.
WARNING:
If the baud rate is changed from the factory default, you may want to record this on the repeater
enclosure for other maintenance staff.
SET GAIN
Purpose:
Used to set the amplifier gain.
Syntax:
set gain {50…62}
Example:
Type:
SET GAIN 56
Response:
> Gain = 56dB