RFD900x Data Sheet
www.rfdesign.com.au
10
Last update 09/07/2018
4
Asynchronous Network
The asynchronous mesh firmware offers a straight forward communication option that allows the user
to quickly transmit and receive data between two or more all nodes. Figure 4-2 depicts this
communication topology. If all the nodes are within range and have compatible parameters,
communication between them will succeed.
Figure 4-2: Asynchronous non-hopping mesh topology
Each node can only communicate to other nodes within its RF range. Also, it is mandatory to assign a
different node id to each node for the network to work properly. An example of setting the NODEID of
the modem:
ATS10=5
AT&W
ATZ
It is possible to address data to a remote node. To do so, set the DESTID parameter to be the same as
the node id of the target. For example:
ATS11=6
AT&W
ATZ
Node 1
Node 2
Node 3
Node 0
Node 4
All nodes within range