background image

 

NOTE! LNB supply voltage must be fed only from one tuner to each LNB. For other receivers must be 
selected Power OFF or use DC-blocked splitters.
Power voltage is connected to the left side AC connector.

PC is connected to RJ 45 connectors with ethernet cable.

3. Setting up the system

The system is programmed with PC via a Web browser. 

1. Connect Ethernet cable from RJ 45 connector to computer.
2. Open the web browser like IE, Firefox, Chrome etc…
3. Write to address  field 192.168.0.145 and then enter.
4. Unit asks the password.

The factory default password is 

Ramsen8262

5. After right password is fed following screen displays.

RF-Tuote Oy,Joensuunkatu 13, 24100 Salo, tel. +358-2736 6360, fax. +358-2-736 6360, 

[email protected]

, 

www.rf-tuote.fi

    

Summary of Contents for RFQ-845T2CI1

Page 1: ...RFQ 845T2CI1 Quadtro DVB T T2 C S S2 S2X to DVB T2 HD remux modulator User Manual RF Tuote Oy Joensuunkatu 13 24100 Salo tel 358 2736 6360 fax 358 2 736 6360 info rf tuote fi www rf tuote fi...

Page 2: ...r 7 Tuner 3 lock LED 8 Tuner 4 Input connector 9 Tuner 4 lock LED 10 Modulator indication LEDs for a mod1error b mod1 ok c mod2 error and d mod2 ok e mod3 error f mod3 ok g mod4 error and h mod4 ok 11...

Page 3: ...ng up the system The system is programmed with PC via a Web browser 1 Connect Ethernet cable from RJ 45 connector to computer 2 Open the web browser like IE Firefox Chrome etc 3 Write to address field...

Page 4: ...age EN or DE 4 DVB configuration 4 1 Tuner To set tuner parameters go to INITIALIZATION For satellite signal set all parameters for terrestrial cable signal only frequency is needed Set the correct pa...

Page 5: ...ymbol of wanted modulator 1 4 Then the symbol is highlighted Then set the wanted LCN and audio language LCN setting works only in the set top boxes which support LCN function RF Tuote Oy Joensuunkatu...

Page 6: ...n selection may be needed for some set top boxes for LCN setting to work properly When all parameters are selected press SAVE CHANGES RF Tuote Oy Joensuunkatu 13 24100 Salo tel 358 2736 6360 fax 358 2...

Page 7: ...ou can select output channel constellation FEC coderate bandwidth guard interval transmission mode and output level If necessary you can also fine tune output frequency You can see also fullness degre...

Page 8: ...utput connectors F female 75 ohm Power consumption 16VDC 20W Dimensions W H D 72mm 218mm 129mm This symbol on the product or on its packing means that within the European Union the product must be tak...