1. Purpose of use

KV-87 regenerates incoming DVB-T mux to other frequency. This manual is valid for both single (KV-
87S) and twin (KV-87T) models.

2. Installation

The connections and indications are shown in Fig 1.

1. Control switch to program a unit. The unit is 
programmed in “ON” position.  The switch must be set 
to “OFF” position when programming is ready

2. Channel number ( CCIR) 

3. Cable-TV S channel indicator led

4. The signal led shows that the unit is powered 

or 

that the unit is powered 

5. Signal led indicates that receiver is locked to 
selected input multiplex selected transport stream

6. ANT IN 

7. USB ports are for software update

8. RF OUT 

9. DC IN  

10.Not in use 

units in chain in stand-alone 

installation)

11. VIDEO/AUDIO connectors for monitoring

12. IR detector

13. Not in use

14. Signal led of output TS. Green = output signal OK, 
red = parameters are not selected correct

KV-87 directly on the wall. Do not cover the air passage holes.

Signals from antenna are fed to IEC-connector at the top of unit.

Power supply is connected to DC connector at the bottom of unit.

RF OUT  is connected to cable network. 

VIDEO/AUDIO connectors (11) are for monitoring the unit while programming.

3. Programming

The receivers and modulators are simple to program with the remote control unit (RCU-800). The main 
functions of RCU are shown in Fig 2.