QS-TRAPTX-1 

Press SET Sw 

2X

LED1 

flashes 2x

Press SET Sw To select 

LED1 OFF: 

STATE Change

LED1 ON: 

Continuous

After selecting wait for 

timeout

Wait 3 

Seconds

LED 1 & 2

Flash 1x, then

LED1 is either 

ON or OFF indicating 

current Status

To Set Continuous or State Change RF Transmissions

 

Replacing transmitter batteries: 

Follow the diagram to replace the 3xAAA batteries. 

When a TRAP switch is pressed a “Switch Down” RF signal is 
transmitted. When a Trap switch is released a “Switch Up” RF 

signal is transmitted. 
 
Continuous Transmit 

TRAP continually (in bursts) transmits “Switch Down” for as long 

as switch is pressed.  
If the Acknowledgment is ON the receiver will reply after each RF 
transmission burst.  
This is ideally suited to momentary operation where the receiver 
output needs to be active as long as the user presses down a 
TRAP Switch. 
 
State Change Transmit 
TRAP transmits an RF transmission only when a Trap switch is 
pressed or released (i.e. on a switch change of state). 

On each of these “state changes” TRAP transmits up to 4  
transmissions, or, “RF packets” (which can be seen by the 

GREEN LED flashing up to 4 times,  
If the Acknowledgment is set to ON the receiver will reply        
immediately.  Upon receiving an Acknowledgment the TRAP will 
cease sending any remaining of the 4 transmissions. 