MAINSLINK-PRO
DS-MAINSLINKPRO-2
PATENT PENDING
Jumper Link Setting
There are three Jumper Links which may be used to configure the following
Link
Open
Fitted
WDOG
Watchdog Active
MODE
LORA Mode 3
LORA Mode 7
MOM/LAT
Momentary
Latching
N N
L
Permanent
LIVE FEED
Li
n
(L
IV
E
IN
)
Lo
ut
(L
IV
E
O
U
T)
Lin
Comm
Lout
WDOG
MODE
MOM/LAT
WDOG - WATCHDOG
When the WDOG link is fitted each MAINSLINKPRO automatically sends a background watch-
dog RF signal and expects to receive a corresponding WDOG signal from its partner.
If the WDOG signal is not received within 90seconds, the output will drop out and comms LED
will flash.
This provides improved reliability and security useful in noisy or poor reception areas.
MODE
LORA Mode 3,
Faster operation shorter range (Line of sight upto 3Km / 500m in buildings)
This mode is recommended for general operation,
LORA Mode 7
, Slower operation Long range (Line of sight upto 5Km / 1Km in buildings)
This mode can be used where additional RF penetration / range is required
Note! In this mode a transmitted signal can take 2 seconds to trigger the receiver.
MOM/LAT - Momentary or Latching
Sets the Relay changeover contacts to operate as Momentary or Latching.
MOMENATRY
: used for MAINSLINK TO MAINSLINK
LATCHING
: is used when MAINSLKINK is being controlled from an RF Solutions hand held Re-
mote transmitter.
Switching Lower Power LED Lights
Mainslink incorporates a “snubber” protection circuit which
is recommended when motor switching. This is incorpo-
rated when Jumper Link J2 is connected between pins 1 & 2
(horizontally across the top pins)
If using MAINSLINK to switch lower power LED lighting the
snubber circuit can cause the LED lights to faintly glow.
To remove this the snubber circuit can be removed by taking
out the Snubber Jumper link as the image shows