SWITCHING 

LIVE 

IN / OUT 

N     E     N

L

Permanent        

LIVE Supply

  

L

IV

E

 IN

PERMANANT

SUPPLY

WDOG

MODE

MOM/LAT

L

(L

IV

E

 O

U

T

 N

/C

)

L

(L

IV

E

 O

U

T

 N

/O

)

Installation 

Multiple System Operation 
Each MAINSLINK-PRO system contains a unique identity so multiple systems can operate within the 
same area without interfering with each other. 

Connect the Supply to both units  
Connect the permanent LIVE Feed and NEUTRAL supply.  

Connect the Switched Input Lin  
Connect the Switching Live input to Lin 

When the Switched Live input (LIVE IN) is ‘LIVE’ the 

LED 

will illuminate, and the Lout at the other        

MAINSLINK-PRO will then switch Live out. 

Connecting the Switching Load Lout 
Connect your LOAD to Lout  

When the Switched Live Output (LOUT) is ‘LIVE’ the 

Red 

LIVE OUT LED will illuminate. 

  

COMMS LED  

ON 

One Flash 

Two Flashes 

3 Flashes 

Operation  

 

 

 

 

Status 

RF Link OK 

Out of range 

Powered  

But unpaired 

In Pairing Mode 

Description 

System  

operating OK 

No RF connection 

to other  

MAINSLINK-PRO  

Waiting to be 

paired to another  

MAINSLINK-PRO 

Actively sending an RF 

‘Please Pair message’

 

Indicates  

Input is LIVE 

Coms Indicates RF 

Link Status  

Indicates 

Output is 

LIVE 

MAINSLINK-PRO 

Page: 3 

QS-MAINSLINKPRO-4 

PATENT  No 2564512 

SWITCHING 

LIVE 

IN / OUT 

  

PERMANANT

SUPPLY

WDOG

MODE

MOM/LAT

Jumper Link Setting

 

There are three Jumper Links which may be used to configure the following: 

Link 

Open 

Fitted 

WDOG 

Watchdog OFF 

Watchdog Active 

MODE 

LORA Mode 3  

LORA Mode 7 

MOM/LAT 

Not Used 

WDOG - WATCHDOG  

This provides improved reliability and security useful in with electrically noisy Loads.  
When the WDOG link is fitted each MAINSLINKPRO automatically sends a background watchdog RF signal 

and expects to receive a corresponding WDOG signal from its partner.  
If the WDOG signal is not received within 90seconds, the output will drop out and comms LED will flash.  

MODE 

LORA Mode 3 

 Faster operation shorter range (Line of sight upto 3Km/500m in buildings) 

LORA Mode 7 

 Long range (Line of sight up to 5Km/1Km in buildings) 

NOTE! In this mode a transmitted signal can take 2 seconds to trigger the receiver. 

MOM/LAT - 

Must be left OPEN for correct operation.  

1. Apply a 230Vac supply to the first MAINSLINK-PRO 

2. Briefly place a magnet across enclosure (Right side as shown) to 

activate the internal reed switch.  

3. The GREEN comms LED will flash 3 times to show in Pairing Mode 

Advanced Operation

Pairing together two MAINSLINK-PROs  

NOTE: This system does not require pairing, they are supplied ready to operate!

 

Erasing a MAINSLINK-PRO 

4. Apply 230Vac to the second MAINSLINK-PRO  

5. Briefly place a magnet across enclosure (Right Side as shown) to 

activate the internal reed switch. 

6. The GREEN comms LED will flash 3 times to show in Pairing Mode 

7. The two MAINSLINK-PRO units which will now auto pair together 

(allow 30 secs -Green Comms LED will stay on.) 

To erase the system hold a magnet beside the Right Side of the      
enclosure for 10 seconds as shown. 

Repeat this process on both units to erase system. 