background image

HORNET PRO  

DS

-

HORNETPRO

-

2          

 

 

 

Systems Part Numbers

 

Additional Transmitters 

Part Number 

Description 

Power Supply

 

HORNETPRO-8S1 

1 channel System  

12-30Vac/dc  

HORNETPRO-8S2 

 2 channel System 

HORNETPRO-8S3 

3 channel System  

HORNETPRO-8S4 

4 channel System  

Custom Systems 

Fobber keyfobs can be customised with  logo, col-

our or complete custom plastic housing for unique 

Branding 
Please contact Sales for further info. 

 

Part Number 

Description 

Range*

 

FOBBER-8T1 

1 Sw  

200m 

FOBBER-8T2 

 2 Sw 

200m 

FOBBER-8T3 

3Sw  

200m 

FOBBER-8T4 

 4 Sw 

200m 

FOBBER-8T6 

4 ch 6 Sw   

200m 

FOBBER-8T8 

 8 Sw 

200m 

FOBBER-8TL1 

2 button 1ch ON/OFF  

200m 

FOBBER-8TL2 

 4 button 2ch ON/OFF 

200m 

Part Number 

Description 

Power Supply

 

HORNETPRO-8R4 

4 ch Receiver  

12-30Vac/dc 

HORNETPRO-8R2M 

2 ch Receiver  

230Vac 

Additional Receivers 

Part Number 

Description 

Power Supply

 

HORNETPRO-8S1M 

1 channel System  

230Vac 

HORNETPRO-8S2M   2 channel System 

Summary of Contents for HORNETPRO Series

Page 1: ...ystems supplied ready to Go Description A versatile general purpose Remote Control System for many different applications Housed in a rugged IP68 weatherproof enclosure The new HORNETPRO system is ide...

Page 2: ...using for unique Branding Please contact Sales for further info Part Number Description Range FOBBER 8T1 1 Sw 200m FOBBER 8T2 2 Sw 200m FOBBER 8T3 3Sw 200m FOBBER 8T4 4 Sw 200m FOBBER 8T6 4 ch 6 Sw 20...

Page 3: ...and power is applied to the Load 1 Open the enclosure by removing fixing screws from the enclosure 2 Remove the antenna and slide out the circuit board 3 Connect the power supply screw terminals 4 Wi...

Page 4: ...ed Mom Mom Mom Mom Closed Closed Latch Latch Latch Latch 12 30V Receiver Place Link Cap horizontally Advanced Operation Configuring receivers The link pins LK1 and LK2 set the action of the relays 1 2...

Page 5: ...of transmitters Erasing Receivers Memory 1 Press and hold the receiver Learn Switch for 5 seconds 2 The receiver will sound a long Beep to confirm erased NOTE You cannot erase individual Tx encoders L...

Page 6: ...esses p day Dimensions 90 x 54 x 27 mm Changing the Battery Remove the 2 enclosure screws replace battery taking care of contacts and the battery polarity Receiver Unit Enclosure Rating IP68 Dimension...

Page 7: ...Ltd fulfills its WEEE obligations by membership of an approved compliance scheme Waste Batteries and Accumulators Directive 2006 66 EC Where batteries are fitted before recycling the product the batte...

Reviews: