background image

FOBOEM Telemetry system 

DS-FOBOEM-2 

 

Operation 
The ZPT module will remain in a low power listening mode at all times when power is present and 

the Sleep Input is Low. When a valid RF signal is received ZPT will wake and process the RF 

packet.  

if the received RF Packet is from a Transmitter that has been “Paired” to the ZPT module, the 

Digital Telemetry outputs are asserted accordingly.  
The RF Packet Data is always presented at the Serial data output to the host. 
 

Pairing Process  
This process creates a paired link between an input button on a transmitter with one of the ZPT 

Digital Telemetry outputs. Any input from any transmitter can be paired to any output of the 

ZPT module. 
 
1. Briefly GND Pin 5, the LED will flash once - this shows OP1 is selected 

2. GND Pin 5 again after release the LED will flash twice  to show OP2 is selected 
3. Repeat above process to select OP3 or 4 

4. With the desired output selected (and before a 10sec timeout) 

5. Press the button or activate the input on the transmitter to be paired. 

6. This will complete the pairing and the LED will flash twice to confirm 

Memory: maximum storage is 30 pairings. 

 
Erase 
To erase the ZPT memory and remove all stored transmitter pairings you must connect the 
Learn  

Pin (5) to Ground for 10 seconds. 

The Learn LED will illuminate while the pin is grounded and after it is disconnected will flash 3 
times to Confirm memory erase has been completed. 

 

Outputs 

Outputs are LVTTL / LVCMOS at Vcc and are Active high. 

 
Momentary or Latching Function 
ZPT actions transmitter button state change only, therefore momentary mode requires receipt 

of a “button down/input active” packet and a “button up/input not active” packet from a trans-

mitter. In momentary mode on receiving a “button down” the ZPT will hold its output active until 
a “button up” is received. In latching mode ZPT must see “button down” then “button up” in or-

der to make a state change to assert or relax an output. 

Mode  

LED 

Description 

Normal operation    

OFF 

No RF data is being transmitted/received 

Flickering 

Module is receiving data 

Learn and erase 

 

ON 

 

Flashes 

 

While input is connected to GND  

(i.e. during button press). 

Flashes to show output selection and  

paring success 

Learn mode times out after 10 seconds 

Flashing twice 

ZPT pairing successful 

Flashes three 

times 

ERASE successful 

Summary of Contents for FOBOEM-4S4

Page 1: ...vity Range when used with FOBBER Keyfob up to 200metres TRAP Handset up to 1000metres ZPT T up to 2000m SABRE Handset up to 2000metres SMT or SIL package self test mode Incorporated CE compliant for E...

Page 2: ...andset will affect the maximum achievable range of operation TRAP Handset A medium sized rugged handset available as 1 2 3 4 6 8 16 buttons Operating up to 1000m TAURUS Handset A rugged IP68 industria...

Page 3: ...to GND to enter Learn Mode 6 SERIAL O P Out Serial Data output to Host micro 7 N C No Connect 8 MOM LATCH In Set outputs as momentary or latching in opera tion Internally tied high Connect to GND for...

Page 4: ...g and the LED will flash twice to confirm Memory maximum storage is 30 pairings Erase To erase the ZPT memory and remove all stored transmitter pairings you must connect the Learn Pin 5 to Ground for...

Page 5: ...puts IP1 8 IP9 16 made up of two 8 bit bytes The low order byte is sent first representing inputs 8 down to 1 where the MSB is input 8 and the LSB is input 1 The high order byte is sent next represent...

Page 6: ...ut Vcc Vcc Description This example shows a ZPT module receiver with all 4 outputs connected Note The external learn switch and learn LED are both shown connected in this example 1 3 4 5 2 6 16 11 10...

Page 7: ...m other radio transmitters For evaluating the local environment please see our RF Meter DS006 In very worse case applications the range quoted may be reduced dramatically below the opti mal range stat...

Page 8: ...metry system DS FOBOEM 2 Mechanical dimensions 16 50 19 25 2 54 D 1 00 1 00 2 00 17 50 1 20 3 00 PCB pad Layout 2 54 13 00 11 75 6 00 2 50 1 00 0 65 16 50 19 25 2 54 D 1 00 13 00 D Package Surface Mou...

Page 9: ...C 60 100s Peak temperature TP 2400 C Time at TP 10 20sec Ramp down rate 60 C s Time from 250 C to peak 8 mins max Zetaplus telemetry module version identifica Single Pink dot indicates ZPT Receiver mo...

Page 10: ...nt Module is in RF Data receive mode 16 mA AC Characteristics Parameter Symbol Test Condition Min Typ Max Unit RX channel bandwidth 60 kHz Image rejection ImREJ Rejection at the image IF 468 35 dB Spu...

Page 11: ...s dokumendis on direktiivin 2014 53 EU mukainen EU vaatimustenmukaisuusvakuutuksen t ysimittainen teksti on saatavilla seuraavassa internetosoitteessa www rfsolutions co uk FR Le soussign RF Solutions...