FOBOEM Telemetry system
DS-FOBOEM-2
Electrical Characteristics
Parameter
Symbol
Test
Min Typ. Max Unit
Supply voltage range
V
cc
1.8 3.3
3.6
Power saving modes
I
Sleep
Module asleep with shutdown pin active.
Note all outputs are disabled
—
<1
uA
RX mode current
Module is in RF Data receive mode
—
16
—
mA
AC Characteristics
Parameter
Symbol
Test Condition
Min
Typ.
Max
Unit
RX channel bandwidth
60
kHz
Image rejection
Im
REJ
Rejection at the image
IF = 468
–
35
dB
Spurious emissions
P
OB_RX1
Measured at RX pins
–
54
dBm
DC characteristics
Parameter
Symbol
Notes
Ambient Tempera-
ture
Supply Voltage
I/O Drive Voltage
V
GPIO
Operating Fre-
quency
868MHz version
915MHz version
915.
00
896.500
915.
27
MHz
RX Sensitivity
-121
dBm