background image

FOBOEM Telemetry system 

DS-FOBOEM-2 

Applications 

• 

Remote control 

• 

I/O Telemetry devices 

• 

Remote switching 

• 

Remote traffic lights 

 

Part No 

Description

 

FOBOEM-4S4 

4 Switch Fob,  SMT ZPT Receiver module with pins Bundled 433MHz   

FOBOEM-8S4 

4 Switch Fob,  SMT ZPT Receiver module with pins Bundled 868MHz   

Features 

• 

Easy Embedded Remote Control  

• 

4 digital outputs  

• 

Serial Data output 

• 

Minimal external components 

• 

Secure data protocol  

• 

Ultra low power 1.8

3.6V  

• 

Easy pairing process 

• 

-121dBm Receive Sensitivity  

• 

Range when used with:  

• 

FOBBER Keyfob up to 200metres 

• 

TRAP Handset up to 1000metres 

• 

ZPT-T up to 2000m 

• 

SABRE Handset up to 2000metres 

• 

SMT or SIL package 

• 

self test mode Incorporated 

• 

CE compliant for EU licence free use 

Description 

FOBOEM provides an easy “plug and Play” Remote Control. 

 

The ZPT Receiver module is an easy design into any circuit, and requires very few ad-

ditional components. When incorporated the ZPT Receiver module automatically out-

puts the serial data of any FOBBER Keyfob. Using the Easy LEARN Process  

the ZPT can be paired with many FOBER keyfobs, which, when operated will cause 

the ZPT Digital outputs to be activated.  

 

Part Numbers 

Header Pins 

ZPT Module 

FOBBER-8T4 

Summary of Contents for FOBOEM-4S4

Page 1: ...vity Range when used with FOBBER Keyfob up to 200metres TRAP Handset up to 1000metres ZPT T up to 2000m SABRE Handset up to 2000metres SMT or SIL package self test mode Incorporated CE compliant for E...

Page 2: ...andset will affect the maximum achievable range of operation TRAP Handset A medium sized rugged handset available as 1 2 3 4 6 8 16 buttons Operating up to 1000m TAURUS Handset A rugged IP68 industria...

Page 3: ...to GND to enter Learn Mode 6 SERIAL O P Out Serial Data output to Host micro 7 N C No Connect 8 MOM LATCH In Set outputs as momentary or latching in opera tion Internally tied high Connect to GND for...

Page 4: ...g and the LED will flash twice to confirm Memory maximum storage is 30 pairings Erase To erase the ZPT memory and remove all stored transmitter pairings you must connect the Learn Pin 5 to Ground for...

Page 5: ...puts IP1 8 IP9 16 made up of two 8 bit bytes The low order byte is sent first representing inputs 8 down to 1 where the MSB is input 8 and the LSB is input 1 The high order byte is sent next represent...

Page 6: ...ut Vcc Vcc Description This example shows a ZPT module receiver with all 4 outputs connected Note The external learn switch and learn LED are both shown connected in this example 1 3 4 5 2 6 16 11 10...

Page 7: ...m other radio transmitters For evaluating the local environment please see our RF Meter DS006 In very worse case applications the range quoted may be reduced dramatically below the opti mal range stat...

Page 8: ...metry system DS FOBOEM 2 Mechanical dimensions 16 50 19 25 2 54 D 1 00 1 00 2 00 17 50 1 20 3 00 PCB pad Layout 2 54 13 00 11 75 6 00 2 50 1 00 0 65 16 50 19 25 2 54 D 1 00 13 00 D Package Surface Mou...

Page 9: ...C 60 100s Peak temperature TP 2400 C Time at TP 10 20sec Ramp down rate 60 C s Time from 250 C to peak 8 mins max Zetaplus telemetry module version identifica Single Pink dot indicates ZPT Receiver mo...

Page 10: ...nt Module is in RF Data receive mode 16 mA AC Characteristics Parameter Symbol Test Condition Min Typ Max Unit RX channel bandwidth 60 kHz Image rejection ImREJ Rejection at the image IF 468 35 dB Spu...

Page 11: ...s dokumendis on direktiivin 2014 53 EU mukainen EU vaatimustenmukaisuusvakuutuksen t ysimittainen teksti on saatavilla seuraavassa internetosoitteessa www rfsolutions co uk FR Le soussign RF Solutions...