U S I N G I N T E R N A L M E N U C O M M A N D S
©
©
©
© RF Innovations Pty Ltd, 1998
Page: 47
223889, Revision 2.2
Channel 1 2 3 4 5 6 7 8 9 10 11
Signal -098 -099 -097 -126 -100 -104 -095 -102 -099 -098 -103
Noise -122 -120 -124 -126 -123 -124 -131 -126 -122 -128 -129
Channel 12 13 14 15 16 17 18 19 20 21 22
Signal -123 -104 -098 -095 -100 -103 -102 -097 -099 -095 -099
Noise -123 -123 -128 -128 -123 -123 -122 -123 -125 -127 -125
Channel 23 24 25 26 27 28 29 30 31 32 33
Signal -096 -104 -102 -099 -096 -098 -100 -127 -105 -103 -100
Noise -125 -122 -129 -128 -132 -120 -127 -127 -132 -122 -130
Channel 34 35 36 37 38 39 40 41 42 43 44
Signal -102 -096 -100 -097 -099 -103 -102 -097 -095 -101 -105
Noise -130 -125 -121 -127 -125 -120 -127 -121 -125 -130 -125
Channel 45 46 47 48 49 50 51
Signal -101 -104 -097 -099 -102 -098 -096
Noise -124 -121 -125 -125 -128 -120 -128
Average signal = -95
Average noise = -112
Press Any Key to continue or ESC to quit
Figure 6-35 Example of a Channel Signal/Noise Log
(L) Show Logging
This function is the same as the in the Radio Statistics Menu explained previously.
(M) Test Link Margin
This function displays the average signal and average noise the radio modem is measuring.
If the unit is configured as a Master then it will require an address of the Slave.
Enter Remote Tx Address value (0-9999):
When selected, a test is started, and the following message is displayed.
The test output is the same as that shown below. The Diagnostic menu is then displayed again.
Testing Link Margin - Please Wait
(2) Display Tasks
The Tasks, which are displayed below in Figure 6-36 are assigned to the radio’s controller when they are
enabled. These tasks are performed at predetermined times by the controller and do not affect the
transfer of data. It is an indication of the amount of work the controller is doing. Tasks are added or
removed from the list as functions are enabled or disabled by the user.