INT
R/W
Verify or Set the trailing character count
(0 to 3)
u
CHAR
R/W
Verify or set end of line termination character
( A - Z, 0 - 9, a - z or ASCII \0x00 ….\0x0D)
CHAR
R/W
Verify or set separating character between the facil-
ity code and ID data( A - Z, 0 - 9, a - z or ASCII \0x00
….\0x0D) Ex: 123 ; 456789
CHAR
R/W
1st character sent when card is removed
( A - Z, 0 - 9, a - z or ASCII \0x00 ….\0x0D)
CHAR
R/W
2nd character sent when card is removed
( A - Z, 0 - 9, a - z or ASCII \0x00 ….\0x0D)
BOOL
R/W
IF True, enable echo of user input and use of backspace
key
BOOL
R/W
IF True, enable RF IDeas command prompt
INT (hex) R/W
Verify or set the logical unique identifier as 16 bit INT
(0x0000..0xFFFF)
Function
Read the device part number
Function
Read firmware version (major . minor . variant)
BOOL
R/W
IF True, use 64 bit math on ID data
BOOL
R/W
IF True, use 64 bit math on facility code data
INT
R/W
Verify or set Length of facility code output
(up to 25 digits)
BOOL
R/W
IF True, enable facility code output as hex
BOOL
R/W
Enable output of facility code
BOOL
R/W
Set to True to separate ID and FAC. False processes ID
and FAC together.
BOOL
R/W
IF True, hex ID data is output in lowercase
BOOL
R/W
Verify or Set ID data length (0 to 25 digits) Note: If
value is shorter than actual Id length the left most
significant digits will be truncated
BOOL
R/W
IF True, enable ID data output as hex
Function
View menu of commands, summary of output types
and variable options
BOOL
R/W
Beeper output control True=beep, False=silent
BOOL
R/W
Continuous read mode True=continuous
output, False=single output of credential data
BOOL
R/W
IF True, enable Quiet mode. (IE: Credential data is not
displayed) Note: data can still be retrieved using
function rfid:qid.
INT
R/W
LED output control 0=off, 1=
red
, 2=
green
, 3=
Amber
(Immediate out w\o write)
255=Automatic control by reader (requires write to
flash) red on standby, green when credential is read
52
Chapter 4
ASCII Command Protocol
Summary of Contents for pcProx Plus
Page 1: ...99009010 Rev U pcProx Plus pcProx Enroll Wiegand Converter Configuration Utility User Manual...
Page 6: ...ID Card Reader System Output Formats 6 Chapter 1 The Basics...
Page 10: ...10 Chapter 2 Hardware Interface Connectors OUTPUT CONNECTORS T...
Page 34: ...34 Chapter 3 Software GetQueuedID Data Display HH MM SS displays 00 00 06...