Reznor HYDRONIC UNIT HEATERS Installation, Operation And Maintenance Manual Download Page 3

The big tube diameter reduces the water
pressure drops. This means more water can
be pumped with less force. It also results in a
very rapid heat-up.

The distance between the fins as well as the
thickness facilitate cleaning and maintenance.
Proper cleaning and maintenance will assure
long life for the unit heaters.

Heat exchangers receive a special paint
coating. This coating adds to the longevity of
the heat exchanger and increases the thermal
efficiency.

Hydronic unit heaters can be operated with
warm water, hot water or steam, at a high
pressure.

The fan is composed of 3 or 6 blades depending
on the size of the heater. Fans have been
statically balanced for reduced noise levels.

The finger proof guard is made of galvanized
steel wire, and is mounted with antivibration
fasteners.

The unit heaters have been tested at independent
laboratory for safety.

The blades can reach a speed of 1,650 rpm.

El gra diametro de los tubos reduce las pérdidas
de carga del agua: esto significa bombasd e
menor potencia y una capacidad de calenta-
miento más rápida.

El ampio espacio entre las aletas y su espesor
facilitan las operaciones de limpieza y de
mantenimiento que son indispensables para
conservar la eficiencia del aerotermo.

El barnizado especial asegura una larga dura-
ción y aumenta el rendimiento térmico.

La bateria es idonea para agua caliente, agua
recalentada o vapor, incluso de alta presión.

El electroventilador está compuesto por una
turbina con álabes en aluminio equibrada
estáticamente.

Los aerotermos han sido sometidos a todo
tipo de pruebas en el Instituto indipendente.

Le grand diamètre des tubes réduit les pertes
de chargement de l’eau; ceci signifie que la
pompe est limitée de puissance et que la
capacité de chauffage est très rapide.

L’ample espacement entre les ailettes et leur
épaisseur facilitent les opérations de nettoyage
et d’entretien indispensables pour conserver
l’efficacité de l’aérotherme.

La peinture spéciale assure une longue durée
et augmente le rendement thermique.

La batterie est apte à l’utilisation de l’eau
chaude, de l’eau surchauffée ou de la vapeur,
même à haute pressione.

L’électroventilateur est composé d’un ventilateur
hélicoïdale à 3 o 6 pâles (pour diminuer
le niveau sonore) en aluminium, équilibré
statiquement.

Les aérothermes essayés à un laboratoire
independent.

3/A

3

 Manuale REZNOR 4050489  17-07-2007  11:21  Pagina 4

 

 

 

Summary of Contents for HYDRONIC UNIT HEATERS

Page 1: ...U S S S S A A A A 1 1 1 16 6 6 61 1 1 13 3 3 37 7 7 7 Cod 4050489 C 07 07 E 07 07 INSTALLATION OPERATION AND MAINTENANCE MANUAL FOR HYDRONIC UNIT HEATERS MANUEL D INSTALLATION ET D ENTRETIEN DES AERO...

Page 2: ...s Intercambiadores de calor En los aerotermos de las series HA 12 el intercambiador de calor est formado por tubos de cobre di metro 7 8 22 mm y aletas de aluminio Los tubos de cobre de 0 030 0 75 mm...

Page 3: ...las aletas y su espesor facilitan las operaciones de limpieza y de mantenimiento que son indispensables para conservar la eficiencia del aerotermo El barnizado especial asegura una larga dura ci n y a...

Page 4: ...eils il faut installer un interrupteur de s curit pour arr ter la machine en cas d urgence Les ventilateurs h lico dales peuvent arriver la vitesse de 1 650 t mn Moteur lectrique asynchrome de type fe...

Page 5: ...ente Esto incluye la caldera todo el sistema de tuber as y los aerotermos Durante la instalaci n la mayor a de los sistemas se contaminan con la grasa de las roscas de las tuber as aceites para roscar...

Page 6: ...e bucle cerrado Su instalaci n en un sistema de agua caliente abierto puede ocasionar un incremento excesivo de productos qu micos y corrosi n y ser la causa de aver as prematuras CARACTER STICAS QU M...

Page 7: ...5 1 8 130 5 1 8 130 5 1 8 130 5 1 8 130 5 1 2 140 11 13 16 300 11 13 16 300 13 3 4 350 15 3 4 400 17 11 16 450 17 11 16 450 19 11 16 500 21 5 8 550 25 9 16 650 3 4 3 4 1 1 4 1 1 4 1 1 4 1 1 4 1 1 4 1...

Page 8: ...TION MAKE SURE THAT UNIT IS INSTALLED LEVEL NOT TILTING IN ANY DIRECTION IF UNIT IS NOT LEVEL AIR POCKETS OR CONDENSATE STAGNATION COULD CAUSE HEAT EXCHANGER FAILURE The unit heater can be mounted by...

Page 9: ...laci n del difusor opcional para dirigir el aire en 4 direcciones D Con cualquier otro m todo o material que el instalador considere idoneo E No fijar el aparato con los tubos de instalac on CONEXION...

Page 10: ...por se efectua sug n el siguiente esquema PRESI N M XIMA 10 BAR 150 psi RACCORDEMENT POUR EAU CHAUDE Le raccordement pour eau chaude doit tre ex cut selon le sch ma suivant PRESSION MAXIMUM 10 BAR 150...

Page 11: ...pages Make sure the motor is grounded When setting the rotation speed of the motor keep away from the fan After making the electrical connection set the rotation speed of the motor Make sure that the...

Page 12: ...to the heat exchanger The fins can be cleaned using low pressure air blower or pressure washer WARNING When cleaning the fins with a pressure washer be careful not to get the motor wet ELECTRICAL FAN...

Page 13: ...Hp Amper Rating High Speed Power Hp Amper Rating 0 6 0 9 1 2 1 9 3 0 1 8 2 6 3 4 13 0 Sigle Phase 115 Volt 60 Hz 0 3 0 4 0 6 1 1 1 7 0 9 1 1 2 2 6 5 0 014 0 020 0 027 0 048 0 090 0 041 0 070 0 110 0...

Page 14: ...50 1 100 0 070 0 160 1 1 2 6 49 55 1 750 2 300 2 973 3 908 590 773 180 236 145 181 583 729 2 190 238 55 689 69 758 47 883 59 980 140 137 62 58 850 1 100 0 110 0 250 2 2 3 4 52 60 2 200 2 850 3 738 4 8...

Page 15: ......

Reviews: