TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS
NOT-DOLPROREYA-03
NOT-DOLPROREYA-03
UK
Dimensions
GENERALITES
HS
temperature
sensor
“Shutdown” type with automatic restart
once the fault has disappeared
General
mains supply
fault
Mains fuse
General
battery supply
fault
Output fuses on –DC supply
Climatic
Climatic Tropicalised (specially coated)
circuit board
Operating
temperature
-10°C to +55°C
Storage
temperature
-20°C to +70°C
Humidity
10% to 90% (without condensation)
Convection
Forced by thermostat-controlled fan
Housing
Wall-mounted housing in painted
aluminium
Protection
rating
IP20
Mounting
Using 4 x 4mm Ø screws
Overall dimen-
sions (Depth x
Width x Height)
125 x 340 x 360 mm
4.9 x 13.4 x 14.2 inches
190x340x 360
7,5x13,4x 14,2
Weight
6 Kg
11,5 kg
EMC
EN55014-1
SAFETY
EN60335-2-29
Display
Front LED display
Optional remote touch screen
display
Mains
connector
3-point cage terminal for cables with a
cross-section of 10mm2 max
Battery
connectors
M8 pins
Battery sensor
connector
2-point cage terminal for cables with a
cross-section of 1.5mm2 max
Alarm relay
connector
2-point cage terminal for cables with a
cross-section of 1.5mm2 max
External
CAN bus
connectors
2 x RJ11 connectors (CAN bus)
12V 60A 12V 90A 24V 40A 24V 60A 24V 100A
Height A
360 mm (14.2 inch)
Width B
340 mm (13.4 inch)
Depth C
125 mm (4.9 inch)
190 mm
(7.5 inch)
12V 60A - 12V 90A
24V 40A - 24V 60A
24V 100A