![REXROTH RD 500 RD42 Operating Manual Download Page 17](http://html1.mh-extra.com/html/rexroth/rd-500-rd42/rd-500-rd42_operating-manual_1449617017.webp)
RD 500 RD42
Electrical installation
3-5
DOK-RD500*-RD42*******-IB03-EN-P
3.4
Power terminals RD42
A supply module, size Class G is shown in the terminal layout diagram.
The position of the terminals corresponds to the narrower or wider units.
High Voltage. Danger of
electrical shock. Do not touch
electricalconnectionsfor 5
minutes after switching
power off.
Read and follow "Safety
Instructions for Electrical
Drives "manual,DOK-GENE-
RL-DRIVE* * * * * * -SVS...
before operating
DANGER
drive 500
REFU
Display
U1 V1 W1
U 2
U 2
V 2
V 2
W 2
W 2
Legend
X3
Control voltage
terminal strip from left
U1 / V1
W1 PE 121 122
/
/
/
/
C
X2
DC bus
X2
input power connection
with line filter
U1 V1 W1
D
Fig. 3-2: Terminal diagram RD42
3.5
Line filter connection
Terminal
Designation
PE
Protective conductor
U1
V1
W1
Line supply connection, 3 phases L1, L2, L3
U2
V2
W2
Connection to the supply module
Fig. 3-3: Line filter connection