Short designation
System element / product
Description
VCP20
Operator terminal
Variant for assembly
VCP25
Operator terminal
Variant for assembly
Tab.18-1:
Product Short Designations
18.2
Leakage Capacitances
18.2.1
Leakage Capacitance of Motors
The data of the typical leakage capacitance refer to the total capacitance of
the power connections U, V, W against the motor housing. The tables below
contain excerpts from the technical data of motors:
Leakage Capacitance
Type
Leakage capacitance of the component
C
ab
nF
MSM019A-0300-NN-__-___
0,3
MSM019B-0300-NN-__-___
0,7
MSM031B-0300-NN-__-___
0,7
MSM031C-0300-NN-__-___
1,4
MSM041B-0300-NN-__-___
1,3
Last modification: 2008-11-20
Tab.18-2:
MSM019A-0300-NN, MSM019B-0300-NN
Type
Leakage capacitance of the component
C
ab
nF
MSK030B-0900-NN-__-___-____
0,7
MSK030C-0900-NN-__-___-____
1,3
MSK040B-0450-NN-__-___-____
1,3
MSK040C-0450-NN-__-___-____
2,0
MSK043C-0600-NN-__-___-____
2,1
MSK050B-0300-NN-__-___-____
2,1
MSK050C-0300-NN-__-___-____
2,6
MSK060B-0300-NN-__-___-____
2,1
MSK060C-0300-NN-__-___-____
2,1
MSK061B-0300-NN-__-___-____
1,8
MSK061C-0300-NN-__-___-____
2,4
MSK070C-0150-NN-__-___-____
3,8
Last modification: 2008-12-10
DOK-INDRV*-SYSTEM*****-PR06-EN-P
Rexroth IndraDrive Drive Systems with HMV01/02 HMS01/02, HMD01, HCS02/03
Bosch Rexroth AG
287/309
Appendix