B10d value mushroom button
Mechanics:
B10d = 600,000 (acc. to the manufacturer)
Assumption: B10d = 2 × B10
Fault exclusion at < 6050 cycles
B10d value auxiliary contact N/C contact
Electrics:
B10d = 10,000,000 (acc. to the manufacturer)
Assumption: B10d = 2 × B10
Fault exclusion at < 6050 cycles
B10d value auxiliary contact N/O contact
Electrics:
B10d = 10,000,000 (acc. to the manufacturer)
Assumption: B10d = 2 × B10
Fault exclusion at < 6050 cycles
Connection cross section
Min. without wire end sleeve (1 × 0.22 mm
2
)
Max. without wire end sleeve (2 × 1.5 mm
2
)
Tightening torques
0.8 Nm (1.2 Nm max.)
Tab. 7-4: E-STOP button – Technical data
7.3 Machine pushbuttons
Only 24 V (protective extra-low voltage) may be connected to the
machine buttons!
Name
Standard auxiliary switch, N/O contact / N/C con-
tact
Connection voltage
PELV/SELV
Max. current
0.5 A
Connection cross section
Min. without wire end sleeve (1 × 0.22 mm
2
)
Max. without wire end sleeve (2 × 1.5 mm
2
)
Tightening torques
0.8 Nm (1.2 Nm max.)
Tab. 7-5: N/O and N/C contact acc. to DIN EN 60947-6-1 – Technical data
7.4 LED module
Name
LED module
Voltage range
DC (DC voltage)
PELV/SELV
Current consumption
Direct connection 24 V AC/DC
18 mA
Tab. 7-6: LED module – Technical data
Bosch Rexroth AG
Technical data
Machine Control Panels
10/53
DOK-SUPPL*-VAM*15*21*1-IT02-EN-P