6-14
Electrical Data
Rexroth IndraDrive C
DOK-INDRV*-HCS02.1****-PR02-EN-P
The current-depending power dissipation of the power sections illustrated
in the following diagrams is composed of
•
the losses of the mains-supply rectifier
•
the switching losses of the inverter
HCS02.1E-W0012
y-axis:
Power dissipation [W]
x-axis:
Current (rms value) [A]
Fig. 6-14:
Power dissipation power section HCS02.1E-W0012
16 kHz
12 kHz
8 kHz
4 kHz
10 kHz