DIAX04 ELS-06VRS
Description of diagnostic letters F... and E...
5-5
DOK-DIAX04-ELS-06VRS**-WA01-EN-P
Remedy:
Correct the appropriate parameter(s). These times are determined by the
manufacturer of the control system and are specified by the SERCOS
interface.
See also the functional description: "Configuration of the telegram send
and receive times"
C109 Position of data record in MDT (S-0-0009) even
Cause:
Parameter
S-0-0009, Beginning address in master data telegram
contains an even value. This is not permitted.
Remedy:
Parameter
S-0-0009, Beginning address in master data telegram
must
be set to an odd value. These parameters are determined by the
manufacturer of the control system, and are specified by the SERCOS
interface.
See also the functional description: "Configuration of the Telegram Send
and Receive Times"
C110 Length of MDT (S-0-0010) odd
Cause:
Parameter
S-0-0010, Length of master data telegram
contains an odd
value. This is not permitted.
Remedy:
Parameter
S-0-0010, Length of master data telegram
must be set to an
even value. These parameters are determined by the manufacturer of the
control system, and are specified by the SERCOS interface.
See also the functional description: "Configuration of the telegram send
and receive times"
C111 ID9 + Record length - 1 > length MDT (S-0-0010)
Cause:
Parameter(s) are set incorrectly for
S-0-0009, Beginning address in
master data telegram
and
S-0-0010, Length of master data telegram
.
The length of the record in MDT for the drive plus the starting address in
MDT is greater than the total length of the MDT.
Remedy:
The parameters for
S-0-0009, Beginning address in master data
telegram
and
S-0-0010, Length of master data telegram
must be
corrected. Those parameters are determined by the manufacturer of the
control system and are specified by the SERCOS interface.
See also the functional description: "Configuration of the telegram send
and receive times"
Summary of Contents for DIAX04
Page 4: ...About this Documentation DIAX04 ELS 06VRS DOK DIAX04 ELS 06VRS WA01 EN P Notes...
Page 14: ...1 4 Diagnostic Message Descriptions DIAX04 ELS 06VRS DOK DIAX04 ELS 06VRS WA01 EN P Notes...
Page 106: ...6 2 Index DIAX04 ELS 06VRS DOK DIAX04 ELS 06VRS WA01 EN P W Warning symbols 3 1...
Page 113: ......
Page 114: ...Printed in Germany 2 9 1 6 2 8...