18
13
PAUSE / BLAST
The two knobs for spinner and conveyor are also labelled as ‘pause’ and ‘blast’. Press down the Pause button
(spinner) to pause spreading, and press again to resume spreading. If the controller is in pause mode when
powered off, the controller will start back up in pause mode once powered back on.
Press down the blast button (conveyor) to increase the spreading output, and press again or wait for the blast
timer to time out to resume the regular spreading rate.
Remote pause / blast is optional by connecting a momentary switch to the digital inputs on the sensor lead
cable.
When the blast timer is set to zero seconds in the setup screen, both the blast knob and the remote blast switch
work on the momentary mode, holding the switch or knob to activate blasting, release to stop blasting.
If the blast timer is not set to zero seconds in the setup screen, the knob and switch will work on the latched
mode. Press down the blast knob once to blast, blasting will stop once the timeout is reached or by pressing the
knob again will stop blasting before the timeout is reached. The remote blast switch works in the same manner.
Both the blast knob and the remote blast switch can work together, you can turn on blasting using the knob and
turn off from the remote blast switch, or vice versa.
For pause mode, it can be activated / deactivated in parallel either from the pause knob or remote pause switch.
14
UPDATE FIRMWARE
Copy the latest .bin file to the root directory of a USB Program Key and rename it to Rexroth.bin. With the
controller powered “off” insert the USB key into the USB port and then power “on” the controller, the controller
will upgrade the firmware automatically. Unplug the USB stick once “Verified” is shown on the display screen. If
“Verified failed” appears on the display, copy the Rexroth.bin file to the root directory of a blank USB key and
try again.
15
LOGGING REPORT
15.1
Import the logging data to computer
Once logging data is saved on the USB memory key (see section 8.5), it can be viewed on a computer with the
CS-530 Desktop Excel tool (CS530Logging_v3.3.xlsm).
Open the CS530Logging_v3.0.xlsm on your desktop and press the “Import Log Data” icon, the computer will
check to see if a USB log key is present. If log files are found, the truck log data files will be imported into and
displayed in the Region and Truck data field as well as in the data zone. A new dialog window will also pop up to
indicate the completion of the file import.
NOTE: The original log files will be deleted from the USB key.