10
7
MATERIAL CONFIGURATION
There are four solid material under the standard mode and two solid materials with air gate mode. Within the
valves configuration page, the right side of the screen is for the corresponding material configuration.
Using or move from conveyor configuration to material configuration.
7.1
Material Name
Press ENTER to input the different solid material names.
Use up / down arrow to view each material’s settings and press FINSH to select the material.
If CHG is pressed, the system will start to edit the material names. (to a maximum of 4 characters)
After you finish editing the material name, press DONE.
7.2
BLAST RATE
BLAST: The first number is the blast rate for blast in closed loop and the next one is the percent of manual blast.
7.3
APPLICATION RATES
RATE: There are 9 settings of the application rate for each material when the conveyor works in open or close
loop mode.
Press ENTER and then the up / down arrows to browse the rate setting values, and press CHG to edit the
current rate value.
7.4
WT/REV
This setting refers to the weight of material being discharged from the main conveyor / auger for every revolution
of the conveyor motor.
CONVEYOR * 1 SALT
MODE: AUTO BLAST: 0270 M99%
SENSOR: 0050 RATE1: 0032
NULL: 15.0 60.0 WT/REV: 1.00
GAIN: 60% CAL GATE: 05
AUTONULL AUTOCAL
CHG NPAGE START SKIP FINSH
* CONVEYOR 1 SALT
MODE: AUTO BLAST: 0270 M99%
SENSOR: 0050 RATE1: 0032
NULL: 15.0 60.0 WT/REV: 1.00
GAIN: 60% CAL GATE: 05
AUTONULL AUTOCAL
PPAGE NPAGE START SKIP ENTER