ECODRIVE03 Drive Controllers
ECODRIVE03 DKC**.040, DKC**.100, DKC**.200
4-35
DKC**.3-200-7 with CZM01.3 and filter choke GLD12 in
"Single source supply":
0
5
10
15
20
25
30
200
250
300
350
400
450
500
Line input voltage U
N1
3*AC in V
P
ZW
D
in
k
W
Fig. 4-35:
Allowed DC bus continuous power for single source supply
DKC**.3-200-7 with CZM01.3 and filter choke GLD12
DKC**.3-200-7 with CZM01.3 and filter choke GLD12 in
"Group supply without DC bus connection":
No increase in the allowed continuous power!
See page 4-23: "Arranging the Group supply without DC bus connection"
DKC**.3-200-7 with CZM01.3 and filter choke GLD12 in
"Group supply with DC bus connection":
See "DKC**.3-200-7 with CZM01.3 and filter choke GLD12 in "Central
supply":"
DKC**.3-200-7 with CZM01.3 and filter choke GLD12 in
"Central supply":
Further DKC**.3-***-7 devices on the common DC-bus increase the sum
of the available continuous power. The increase can be seen in the
diagram "DKC**.3-***-7 in Single source supply" of each particular device.
The sum of the allowed DC bus continuous power is limited to the
performance specifications of the DKC**.3-200-7 with CZM 01.3and filter
choke GLD12 in Single source supply.
Note:
Definition of terms, see page 4-19: "Mains supply options".
|