background image

Installation and Maintenance Instructions 

 Falk Steelflex

®

(Page 4 of 9) Type T10 & T20

428-111 

Rexnord Industries, LLC, 5555 S. Moorland Rd., New Berlin, WI 53151-7953

02/2012 

Telephone: 262-796-4060   Fax: 262-796-4064 

Supersedes manuals 428-110, 112, 210 - 04/2005 

e-mail: [email protected]   web: www.rexnord.com

4.  Mount Seals (Cover T20) & Hubs

DANGER!

Be sure to disengage the electrical power and any other sources of potential energy before you perform 

work on the hub and coupling assembly.

4.1.  Examine the coupling assembly to insure there is no visible damage.

4.2.  Clean the hub bores and shafts using lint free cloth. Remove any nicks or burrs.

4.3.  When assembled, the key(s) should have a close side-to-side fit in the keyway in the hub and shaft, with a slight clearance over the top of 

the key.

4.4.  Place the seal rings and ½ cover for T20 on shafts before mounting  hubs.

   CAUTION: When heating hubs is required, an oven is preferred and an open flame is not recommended. 

If flame heating is considered mandatory, it is important to provide uniform heating to avoid distortion 

and excessive temperature. A thermal stick applied to the hub surface will help determine the hub 

temperature.

DANGER!

Touching hot hubs causes burns. Wear safety gloves to avoid contact with hot surfaces.

5.  Straight Bore with Clearance/Slip Fit

5.1.  Install the key(s) in the shaft.

5.2.  Check to be sure that the set screw(s) in the hub does not protrude into the keyway or the bore. Remove or back out the set screw to 

provide clearance during assembly.

5.3.  Slide the hub up the shaft to the desired axial position.

T10

T20

Table 1 – Falk Steeflex Coupling Component part numbers

Description

Style

Part

1020T

1030T

1040T

1050T

1060T

1070T

1080T

1090T

1100T

1110T

1120T

1130T

1140T

Seal Kit

T10

1 & 5

0776650 0776651 0776652 0776653 0776654 0776655 0776708 0776709 0707189 0707190 0707191 0707192 0707193

Seal Kit

T20

1 & 5

0706752 0706753 0706754 0706755 0706756 0706757 0706758 0706759 0706760 0706761 0706762 0706763 0706764

Cover Assembly

T10

1, 2, 5, 6, 7 0775804 0775805 0775806 0775810 0775811 0775812 0776214 0776215 0776216 0776217 0776218 0776219 0776220

Cover Assembly

T20

1, 2, 5, 6, 7 0706739 0706740 0706741 0706742 0706743 0706744 0706745 0706746 0706747 0706748 0706749 0706750 0706751

Hub

T10 & T20

3

0246652 0246653 0246654 0246655 0246656 0246657 0246658 0246659 0246660 0246661 0246662 0246663 0246664

Grid

T10 & T20

4

0762810 0762811 0762812 0762813 0762814 0758250 0758251 0758252 0758253 0758254 0758255 0758256 0758257

Fastener Set

T10

6

0775798 0775798 0775798 0775800 0775800 0775800 0776194 0776194 0776196 0776196 0776221 0776221 0776221

Fastener Set

T20

6

0707045 0707046 0707046 0707047 0707047 0707047 0707048 0707048 0707049 0707049 0707050 0707051 0707052

Description

Style

Part

1150T

1160T

1170T

1180T

1190T

1200T

1210T

1220T

1230T

1240T

1250T

1260T

Seal Kit

T10

1 & 5

0725614 0725615 0725616 0725617 0725618 0725619 0725732 0725733 0725734

Seal Kit

T20

1 & 5

0725620 0725621 0725622

Cover Assembly

T10

1, 2, 5, 6, 7, 8, 9 0767950 0767951 0767952 0767953 0767954 0767955 0427516 0427517 0427518 0422233 0422234 0422235

Cover Assembly

T20

1, 2, 5, 6, 7

0706752 0706753 0706754

Hub

T10 & T20

3

0333090 0333091 0333092 0333093 0333094 0333095 0334246 0334247 0334248 0334249 0334250 0334251

Grid

T10 & T20

4

0758258 0758259 0758260 0758261 0758262 0758263 0758264 0758265 0758266 0758267 0758268 0758269

Fastener Set

T10

6

0744116 0744116 0744117 0744117 0744118 0744119 0744120 0744121 0744121

Fastener Set

T20

6

0744122 0744122 0744123

NOTE: 

flush here

NOTE: 

flush here

MOUNT 

SEAL 

FIRST

Summary of Contents for Falk Steelflex T10

Page 1: ...d shaft 1 2 These instructions are intended to help you to install and maintain your Falk Steelflex coupling Please read these instructions prior to installing the coupling and prior to maintenance of the coupling and connected equipment Keep these instructions near the coupling installationandavailableforreviewbymaintenancepersonnel Forspecialengineeredcouplings Rexnordmayprovideanengineering dra...

Page 2: ...onforming to ATEX 2 5 All rotating power transmission products are potentially dangerous and can cause serious injury They must be properly guarded in compliancewithOSHA ANSI ATEX Europeanmachinesafetystandardsandotherlocalstandards Itistheresponsibilityof theuserto provide proper guarding 2 6 For ATEX requirements the guard must have a minimum of 12 7 mm 1 2 inch radial clearance to the coupling ...

Page 3: ...rland Rd New Berlin WI 53151 7953 428 111 Telephone 262 796 4060 Fax 262 796 4064 02 2012 e mail info rexnord com web www rexnord com Supersedes manuals 428 110 112 110 04 2005 3 Components and Part Numbers Figure 2 Falk Steelflex Coupling Components Type T20 Type T10 1020 1140 Type T10 1240 1260 Type T10 1150 1230 ...

Page 4: ...070T 1080T 1090T 1100T 1110T 1120T 1130T 1140T Seal Kit T10 1 5 0776650 0776651 0776652 0776653 0776654 0776655 0776708 0776709 0707189 0707190 0707191 0707192 0707193 Seal Kit T20 1 5 0706752 0706753 0706754 0706755 0706756 0706757 0706758 0706759 0706760 0706761 0706762 0706763 0706764 Cover Assembly T10 1 2 5 6 7 0775804 0775805 0775806 0775810 0775811 0775812 0776214 0776215 0776216 0776217 07...

Page 5: ...he distance from the shaft end to the hub face as shown in Figure 3 Record the dimension 7 5 Mount a dial indicator to read axial hub advancement as shown in Figure 4 Alternatively the indicator can be positioned to contact the end of the hub Set the indicator to zero 7 6 Remove the hub and install the key s in the shaft 7 7 Heat the hub in an oven until the bore is sufficiently larger than the sh...

Page 6: ...d Face Refer to Rexnord bulletin 538 214 Coupling Alignment Fundamentals for instructions regarding shaft alignment 8 1 Close gap coupled couplings Use an inside micrometer or a spacer bar equal in thickness as shown below at 90 intervals to measure the distance between hubs to gap specified in Table 3 8 2 The Angular Misalignment value is the maximum difference between the measurements X and Y ta...

Page 7: ...cant as possible and wipe off excess flush with top of grid T10 Position seals on hubs to line up with grooves in cover Position gaskets on flange of lower cover half and assemble covers so that the match marks are on the same side If shafts are not level horizontal or coupling is to be used vertically assemble cover halves with the lug and match T20 Slide cover halves with seals onto hubs and pos...

Page 8: ...ing Size 1150T 1160T 1170T 1180T 1190T 1200T 1210T 1220T 1230T 1240T 1250T 1260T T10 lb in 650 650 1300 1300 1300 2300 2300 3580 3580 5350 5350 5350 Nm 73 4 73 4 146 9 146 9 146 9 259 9 259 9 404 5 404 5 604 5 604 5 604 5 T20 lb in 650 1300 1300 Nm 73 4 146 9 146 9 Table 7 Angular Operation limits Angular Size 1020T 1030T 1040T 1050T 1060T 1070T 1080T 1090T 1100T 1110T 1120T 1130T 1140T X Y Inch 0...

Page 9: ...lubricant specified on table 9 If coupling leaks grease is exposed to extreme temperatures excessive moisture or experiences frequent reversals or axial movements more frequent lubrication may be required CAUTION Remove grease fitting and make certain all plugs are inserted after lubricating 12 ANNUAL MAINTENANCE 12 1 For extreme or unusual operating conditions check coupling more frequently 12 2 ...

Reviews: