background image

Falk Steelflex Couplings 

 Installation & Maintenance

Type T10 • Sizes 1150 – 1260 & 150 – 260 (Page 3 of 6)

Rexnord 

428-112

5555 S. Moorland Rd., New Berlin, WI 53151-7953 USA 

March 2014

Telephone:  262-796-4060 Fax:  262-796-4060  web: www.rexnord.com 

Supersedes 4-05

Maximize Performance And Life

The performance and life of  couplings depend largely 

upon how you install and maintain them. Before installing 

couplings, make certain that foundations of  equipment 

to be connected meet manufacturers’ requirements. 

Check for soft foot. The use of  stainless steel shims is 

recommended. Measuring misalignment and positioning 

equipment within alignment tolerances is simplified with an 

alignment computer. These calculations can also be done 

graphically or mathematically.
Alignment is shown using spacer bar and straight 

edge. This practice has proven to be adequate for 

many industrial applications. However, for superior final 

alignment, the use of  dial indicators (see Manual 458-834 

for instructions), lasers, alignment computers or graphical 

analysis is recommended.

1— Mount Seals And Hubs

Lock out starting switch of  prime mover. Clean all metal 

parts using a non-flammable solvent. Lightly coat seals 

with grease and place on shafts BEFORE mounting hubs. 

Heat hubs as previously instructed. Seal keyways to 

prevent leakage. Mount hubs on their respective shafts 

so the hub face is flush with the end of  its shaft unless 

otherwise indicated.

2 — Gap and Angular Alignment

Use a spacer bar equal in thickness to the gap specified 

in Table 1, Page 5. Insert bar as shown above, to same 

depth at 90° intervals and measure clearance between bar 

and hub face with feelers. The difference in minimum and 

maximum measurements must not exceed the ANGULAR 

INSTALLATION limits specified in Table 1.

3 — Offset Alignment

 

 

Align so that a straight edge rests squarely (or within the 

limits specified in Table 1) on both hubs as shown above 

and also at 90° intervals. Check with feelers. The clearance 

must not exceed the PARALLEL OFFSET installation limits 

specified in Table 1. Tighten all foundation bolts and repeat 

Steps 2 and 3. Realign coupling if  necessary. NOTE: Use a 

dial indicator for more accurate alignment.

4 — Insert Grid

 

Pack gap and grooves with specified lubricant before 

inserting grid. When grids are furnished in two or more 

segments, install them so that all cut ends extend in the 

same direction (as detailed in the exploded view picture 

above); this will assure correct grid contact with non-

rotating pin in cover halves. Spread the grid slightly to pass 

over the coupling teeth and seat with a soft mallet.

MOUNT 

SEAL 

FIRST

Summary of Contents for Falk SteelfIex T10 Series

Page 1: ...loat kits are recommended for protecting the bearings Falk Steelflex couplings are easily modified to limit end float refer to Manual 428 820 for instructions LUBRICATION Adequate lubrication is essential for satisfactory operation Page 2 provides a list of typical lubricants and specifications for general purpose and long term greases Because of its superior lubricating characteristics and low ce...

Page 2: ...ng Lubricants The values shown are typical and slight variations are permissible DROPPING POINT 300 F 149 C or higher CONSISTENCY NLGI No 2 with 60 stroke worked penetration value in the range of 250 to 300 SEPARATION AND RESISTANCE Low oil separation rate and high resistance to separation from centrifuging LIQUID CONSTITUENT Possess good lubricating properties equivalent to a high quality well re...

Page 3: ...lace on shafts BEFORE mounting hubs Heat hubs as previously instructed Seal keyways to prevent leakage Mount hubs on their respective shafts so the hub face is flush with the end of its shaft unless otherwise indicated 2 Gap and Angular Alignment Use a spacer bar equal in thickness to the gap specified in Table 1 Page 5 Insert bar as shown above to same depth at 90 intervals and measure clearance ...

Page 4: ...xtreme or unusual operating conditions check coupling more frequently 1 Check alignment per steps on Page 3 If the maximum operating misalignment limits are exceeded realign the coupling to the recommended installation limits See Table 1 for installation and operating alignment limits 2 Check tightening torques of all fasteners 3 Inspect seal ring and gasket to determine if replacement is required...

Page 5: ...NMENT END FLOAT TABLE 1 Misalignment and End Float CPLG SIZE Installation Limits Operating Limits Cover Fastener Torque Values Allow Speed rpm Lube Wt Parallel Offset P Angular x y Normal Gap 10 Parallel Offset P Angular x y End Float Physical Limit Min 2 x F Max Inch Max mm Max Inch Max mm Inch mm Max Inch Max mm Max Inch Max mm Inch mm lb in Nm lb kg 1150T 012 305 016 406 250 6 024 610 062 1 57 ...

Page 6: ...use blue grids Older models 150T thru 260T use orange grids CAUTION Blue grids may be used in all applications but DO NOT substitute orange grids for blue CAUTION DO NOT mix cover halves of different designs WARNING Mixing grid coupling components from different manufacturers may cause premature failure and personal or property damage from flying debris PART NUMBERS 1 Seal T10 2 Cover T10 3 Hub Sp...

Reviews: