9
revolution
Revolution Education Ltd. Web: www.picaxe.co.uk
Version 2.0 12/10
AXE110.PMD
PICAXE DATALOGGER
The ‘
Readings
’ box allows the number of mission samples to be selected (up to the
memory limit).
The ‘
Outputs
’ box allows selection of various outputs as follows:
- Use bi-co lo ur LED
If selected, the status LED will flash green every time a reading is taken. When the
mission is complete (or the memory is full) the LED will turn red. If a memory
error occurs, the LED will alternately flash red/green.
- Use piezo so under
If selected, the optional piezo sounder (SPE002) will beep every time a reading is
taken.
- Use speech
If selected, the optional speech module (SPE020) will speak the readings as they are
taken. Note that the SPE020 module is discontinued and no longer available.
- Use serial LCD
If selected, the optional serial LCD module (AXE033) will display the readings as
they are taken.
- Use EE WP o n AXE111
If selected, output6 is used as a write-enable for the AXE111 memory expansion
board. Note this option cannot be used at the same time as the serial LCD option,
as both options use output6. If selected, a jumper wire should be soldered across
the pads marked LK1 on the bottom of the AXE110 datalogger module.