21

20

Turning on the ReLog is a simple 

task! Simply press the On/off but-

ton (          ) and the LED indicator will 

show a steady green light, followed 

by a steady blue light with battery 

status indication every 3 seconds. 

The ReLog is now in standby mode.

4. Using the ReLog

Measuring

Turn the ReLog on

Start measurements

To start measuring, press the Start/

stop button (        )  once. The LED 

indicator will flash in blue 3 times. 

The ReLog is now measuring. 

During measurement, the LED indi-

cator flashes to indicate the battery 

status every 3 seconds.

Stop measurements

To stop a measurement, simply 

press the Start/stop button (            )  

again. The LED indicator will once 

again flash in blue 3 times, and 

the ReLog will go back to standby 

mode.

To turn the logger off, press and 

hold the On/off button (              ) 

for 3 seconds when the logger is in 

stand-by mode. 

Below, you will find an instruction 

on how to proceed to get started 

with your measurements.

Summary of Contents for ReLog L

Page 1: ...ReLog vibration data logger User manual quick start guide for ReLog S ReLog M ReLog L...

Page 2: ...lified as ser vice personnel Do not remove and disconnect the li ion battery from its holder Important information Copyright ReVibe Energy AB 2020 All rights re served Manual version 002 Firmware vers...

Page 3: ...nd press ReLog Settings 4 Choose the ReLog s root folder from the browser window 5 Set the desired sample rate MOUNTING THE RELOG 1 Clean the surface object from dirt grease or similar 2 Choose a suit...

Page 4: ...time clock Yes Logging while charging over USB can be connected to power outlet Yes CE RoHS compliant Yes STORAGE Type of storage Internal SD card Transfer of data Via USB cable to PC Storage size ReL...

Page 5: ...15 6 g 8 192 g Noise density 25 g Hz Analog anti aliasing filter cutoff frequency 1 5 kHz Digital filter Sinc type Drift 0 15 mg C maximum 0 02 mg C typical 2 Technical specifications PRIMARY ACCELERO...

Page 6: ...L 3 400 mAh Minimum capacity ReLog S 2 500 mAh ReLog M 2 900 mAh ReLog L 3 300 mAh Operating temperature 20 C 60 C 4 F to 140 F Storage temperature 1 month 20 C 60 C 4 F to 140 F 3 months 20 C 45 C 4...

Page 7: ...61 44 Interface What is included in the box Interface legend When you receive your ReLog you will find the following items in the box 1 ReLog vibration data logger 1 Connecting USB cable for data tra...

Page 8: ...d flashing every 3 s Starting measure ment flashing Measuring flashing every 3 s Stopping measure ment flashing Update mode flashing 3 Product overview Battery LED indicator COLOUR BATTERY CHARGE STAT...

Page 9: ...gs of your comput er and whether other flash drives are connected Option 2 use the _settings file When connecting the ReLog to a PC you can find the settings file in the ReLog root folder _settings Yo...

Page 10: ...og to ensure that the unit is firmly at tached to the object Mounting methods Mounting by double sided tape This will most likely be the go to option for most users of the ReLog as it is likely that y...

Page 11: ...on once The LED indicator will flash in blue 3 times The ReLog is now measuring During measurement the LED indi cator flashes to indicate the battery status every 3 seconds Stop measurements To stop a...

Page 12: ...content in the signal The resolution of the FFT is direct ly proportional to the length of the measurement and the sample rate used PSD The PSD is based on the FFT algorithm but normalizes the values...

Page 13: ...de This is done by holding the Start stop button while inserting the USB cable into a PC A steady teal light indicates that the device has entered update mode Open VibIn spect and follow the instructi...

Page 14: ...a PC Please allow some time to pass up to 20 seconds as it sometimes might take some time for your com puter to properly read and accept the ReLog as an external device This issue could in particular...

Page 15: ...Copyright ReVibe Energy AB 2020...