Page 1: ...Reverso Pumps Inc www reversopumps com contact reversopumps com Ph 954 522 0882 Manual AFP 150 DC ...

Page 2: ...llation Electrical Installation 4 Piping Installation 5 Initial Setup 6 Digital Timer Instructions Set Date and Time 7 Digital Timer Instructions Set Schedule Timer 8 Digital Timer Instructions Set Manual Timer 9 Digital Timer Alarms 10 Backflushing Instructions 11 Filter Element Replacement 12 Troubleshooting 13 ...

Page 3: ...rial number plate 2 Vacuum gauge 3 Fuel water separator 4 Inlet 5 Water sensors 6 Drain valve Push in and turn counter clockwise to open 7 Control panel 8 Hinged cover covers pump and outlet 9 Outlet 10 2 micron filter 11 Spill sensor 12 Drip pan 13 Pump 1 2 3 4 6 5 7 8 9 10 11 12 13 Wall Mount Version ...

Page 4: ...rvice system light indicates an alarm has been triggered and user must service the system 9 Pump active light indicates fuel polishing system is running 10 Manual timer mode active light indicates system is operating in manual timer mode not schedule timer mode 11 Left key 12 Up key 13 Right key 14 Down key 15 OK key 16 Escape key Control Panel Digital Timer 1 5 6 7 8 9 10 2 3 4 Control Panel Digi...

Page 5: ...p Brass Gear stainless shaft double lip seal Max Lift 5 ft 1 52 m vertical lift lines 1 2 Timer Digital PLC Inlet 1 2 male JIC flare fitting Outlet 1 2 male JIC flare fitting Filter Torque Values Bowl Retainer Ring 8 Nm 105 in lbs Lid 8 Nm 105 in lbs Bleed Screw 6 Nm 50 in lbs Additional Options Enclosure Stand for enclosure The system has been developed to be used with diesel fuel only DO NOT USE...

Page 6: ... not be mounted more than 5 above the tank or farther than 10 Mounting farther than this will require back flow protection Mounting Electrical Installation Installation of unit should only be performed by qualified installation personnel who have thoroughly read and understands the installation instructions covered in this manual To avoid the risk of electric shock make sure that the power supply ...

Page 7: ...he tank If the AFP is mounted below tank top level a priming tee should be installed on the highest point of the suction line to be able to easily prime the systems delivery line The return line s discharge should be connected to the outlet of the pump OUT port and enter the tank as far as possible from the pick up tube For optimal performance ensure that the outlet discharge or return line s are ...

Page 8: ...ON Pump will start upon pressing the start button Pump will automatically shut off after the preset run time Operate in this mode if system will run one set time Choose timer mode Operate in this mode if system will start stop automatically on the programmed days of the week and times Must press manual timer mode button to activate deactivate Manual timer mode light will be OFF Pump will automatic...

Page 9: ...ates your selection Use LEFT RIGHT key to move selection Use UP DOWN key to change date and time Press OK key when finished and to return to previous menu Select Clock option Press OK key to continue 1 2 3 4 5 6 Press ESC key Press ESC key again to return to current time screen Now shown is the current time screen Press UP key to return to program screen 7 8 ESC OK MTWTFSS MTWTFSS 11 00 15 00 ON O...

Page 10: ...t day of the week This flashing underline indicates your selection Use the LEFT RIGHT keys to move between the dates start time and stop time When using this method follow sequence exactly or damage to program can occur non warrantable situation Change the run time With the flashing underline in the days row use the LEFT RIGHT key to move to start time ON Press OK key until flashing box appears Us...

Page 11: ...d hold ESC key until flashing underline appears This indicates your selection Press OK key and flashing box appears Use UP DOWN key to change time The m indicates minutes and can be changed to h for hours When finished press OK key In the screen shown below the system is set to run for 20 minutes and will stop once the time has expired Top row indicates current time Bottom row indicates program ti...

Page 12: ...d in the unit If one of the alarms should sound De energize system when servicing unit 1 Follow the directions displayed on the screen 2 Press RESET STOP button 3 Wait at least 2 minutes then press START to restart the unit If you have successfully cleared the alarms the unit should restart ESC OK HI WATER DRAIN BOWL ESC OK HI PRESS Check Discharge ESC OK HI VAC BACK FLUSH FILTER High Water Alarm ...

Page 13: ...lates to be released from the filter element Allow water and dirt to settle into bowl Large droplets of water and dirt will fall to the bottom of the bowl Drain out the water and dirt that has accumulated in the bottom of the bowl Close drain valve by pushing and turning clockwise Allow dirt and water to settle again As the fuel is drained out of the separator in step 4 more dirt and water will be...

Page 14: ...he handle Replace with new filter element and re fit the spring cassette Step 6 Inspect lid gasket Replace if necessary Step 7 Fit lid checking for correct positioning Evenly tighten in the sequence shown refer to Technical Specifications for torque values Step 8 Open the fuel supply valve prime fuel system and check for leaks Prior to servicing the filters ensure that the unit is OFF 2 3 1 4 2 3 ...

Page 15: ...r plugged Pump has been run dry or insufficient fuel Plumbing on inlet side not appropriately dimensioned Pump requires too much power Air in plumbing lines Liquid too viscous Insufficient fuel supply Air leaks in the inlet pipe Air or gas on the suction side Control power not available Tripped circuit breaker on control board Pump failed and seized Motor failure Check service switch is in the ON ...