10
7.) Bend the holding tabs you selected outward.
8.) Set FAN into place in the opening using holding tabs, now the tabs hold the fan
in position in the ceiling opening.
holding tab
holding tab
holding tab
WARNING:
Disconnect the AC power before any work is done to any part of
the circuit ReVent
®
is connected to. If you do not understand this warning,
seek the services of a qualified licensed electrician.
WARNING:
Copper to copper only. Do
not
use aluminum wire.
WARNING:
Follow all local electrical and safety codes, and NEC (National
Electrical Codes).
CAUTION:
If your house wires do not match these colors, determine what
each house wire represents before connecting. You may need to consult a
qualified licensed electrician to determine this safely.
9.) Disconnect FAN motor from electrical enclosure. Remove the electrical cover
set screw and slide open the electrical enclosure.
remove set
screw
unplug fan
connector
slide