The X-CYCLONE® air cleaner T series with induction system
➜
is nearly maintenance-free!!
You simply
need to clean it at regular intervals.
We recommend that you remove the worktop
to do this and clean the area underneath
thoroughly. Just lift the worktop slightly
(a)
and
extract it to the front
(b)
. Now the area underneath
the worktop is fully accessible and can be cleaned.
We recommend in addition that you
check the level
in the liquid tank at regular intervals.
When the
oil level can be seen in the level inspection glass
(c)
,
you should drain the tank. To do this, open the
oil drain cock
(d)
, collect the running-off liquid
and dispose it.
To remove the liquid collection tank, remove
the safety pins from the cover and push
the flexible socket with the cover upwards.
After this, push the collection tank upwards
and extract it to the front.
a
b
c
d
e
11
Reinigung und Wartung II
Cleaning and Maintenance II