Reveal NR3651RRSV Installation And Operating Manual Download Page 1

Rev B Date: 12.15.2021 

Manuals\Reveal_Over-Under Refrigerated Service Case Operating Manual_21-22964.pub 

Structural Concepts Corporation ∙  888 E. Porter Road ∙ Muskegon, MI  49441  Phone: 231.798.8888  Fax: 231.798.4960  ∙  www.structuralconcepts.com 

 SCC P/N 

21-22964 

INSTALLATION   

AND OPERATING 

MANUAL 

Reveal 

® 

READ AND SAVE THESE INSTRUCTIONS 

REVEAL® FREE STANDING OVER-UNDER REFRIGERATED CONVERTIBLE MERCHANDISERS 

   > CONVERTIBLE UPPER SECTION MAY BE EITHER AMBIENT OR REFRIGERATED 

   > REFRIGERATED LOWER SECTION     

   > SELF-CONTAINED OR REMOTE UNITS 

   > UPPER SECTION: REAR SLIDING DOORS and SINGLE SHELF 

   > LOWER SECTION: REAR SLIDING DOORS WITH PERFORATED  

      ACRYLIC PLENUMS     

   > DEPENDING UPON OPTIONS CHOSEN, LOWER SECTION MAY  

      HAVE NO SHELVING, SHELVING OR RISERS (IN LIEU OF SHELVING) 

   --- --- --- --- --- 

   

> CAUTION! DO NOT PUSH OR PULL ON UPPER GLASS ENCLOSURE! 

   > ONLY USE HANDLES (AT EACH END OF CASE) TO PUSH OR PULL CASE INTO POSITION!

 

Reveal® Model NR3651RRSV /  

Rear Sliding Doors and Acrylic  

Perforated Plenums / Shown As 

Shipped From Factory (Without 

Attached Components) / Rear Slide-

Out Access To Condenser Package 

Reveal® Model NR3658RRSV 

Rear Sliding Doors and Acrylic 

Perforated Plenums / Cladding 

Shown Attached 

Reveal® Model NR3651RRSV 

Rear Sliding Doors and Acrylic 

Perforated Plenums / Optional 

Product Steps / Shown As Shipped 

From Factory (Without Attached 

Components) / Front Slide-Out 

Access To Condenser Package 

Models Are Shipped WITHOUT 

Panels and Cladding Attached.       

See Pages 10 & 11 For Component 

Attachment Instructions. 

Note: Illustrations Shown May Not 

Reflect Every Feature Or Option Of 

Your Particular Model. See Page 3 

Of Manual For List Of Models To 

Which This Manual Is Applicable. 

Summary of Contents for NR3651RRSV

Page 1: ...NG OR RISERS IN LIEU OF SHELVING CAUTION DO NOT PUSH OR PULL ON UPPER GLASS ENCLOSURE ONLY USE HANDLES AT EACH END OF CASE TO PUSH OR PULL CASE INTO POSITION Reveal Model NR3651RRSV Rear Sliding Doors...

Page 2: ...UB AREA AFTER DECK PAN REMOVAL 36 MODELS CASE DESIGN CONT D TUB AREA AFTER DECK PAN REMOVAL 48 60 and 72 MODELS CASE DESIGN CONT D LED LIGHT SWITCH LOCATION LED LIGHTS THERMOMETERS CASE DESIGN CONT D...

Page 3: ...ght Case Depth x Width NR3651RRSV 16 50 3 4 33 D x 35 3 4 W NR3658RRSV 16 57 1 2 33 D x 35 3 4 W NR4851RRSV 16 50 3 4 33 D x 47 3 4 W NR4858RRSV 16 57 1 2 33 D x 47 3 4 W NR6051RRSV 16 50 3 4 33 D x 5...

Page 4: ...are intended for use in an area where environmental conditions are controlled and maintained so that the ambient temperature does not exceed 80 F 27 C and 55 maximum humidity If unsure if your unit is...

Page 5: ...s keep unit at least 15 feet from exterior doors overhead HVAC vents or any air curtain disruption Do not expose to direct sunlight or heat source ovens fryers etc CAUTION CAUTION LAMP REPLACEMENT GUI...

Page 6: ...and OFF case Air intake grille is held in place by magnets Toe Kick No screw removal is required Place air intake grille in secure location while removing case from Skid 3 Disconnect Case From Skid Us...

Page 7: ...ramp if available Slide Skid from under case as required Maintain support of case at all times or center of gravity may cause case to fall See illustration at right 7 Casters Locking After case is at...

Page 8: ...to slots in upright F Nylon thumb screws 4 per shelf secures shelving during shipment Note Remove using pliers if necessary and discard thumbscrews after case is installed so shelves can be disassemb...

Page 9: ...porator fans are rotating Turn on LED light switch located on rear right upright cover See CASE DESIGN CONT D LED LIGHT SWITCH LOCATION section in this operating manual for illustration 10 Toe Kick To...

Page 10: ...ing 2 screws Note Shipping brace that is opposite to air intake side of condenser package shown below is NOT to be removed 13 Attaching Front Panel Components Carefully remove components from packagin...

Page 11: ...ld it firmly in place See illustration below 17 Attaching Rear Grille Use finger holes to place rear grille s inner hooks onto case rear s lower shoulder screws Snap onto case s two 2 rear vertical ma...

Page 12: ...nal Upper Shelving Air Return Grille UV Bonded Glass Upper Air Return Grille Similar Position as Lower Section Convertible Upper Section Ambient Refrigerated Refrigerated Lower Section Handles For Pus...

Page 13: ...movable Rear Doors Lower Section With Rear Doors And Acrylic Perforated Plenums Condenser Package Clean Sweep Coil Cleaner Handles For Pushing or Pulling Unit Into Position Typ Rear Caster Electrical...

Page 14: ...emove base support bracket by removing 4 screws Remove 4 screws from the controller DC driver box cover to access electrical components Note Only certified electricians are to access electrical compon...

Page 15: ...wn in D Air Return A Upper section in ambient state cover in horizontal position preventing airflow into upper section B Air discharge cover shown removed from case via finger holes for illustrative p...

Page 16: ...below reflects single evaporator fan 36 units It is shown after removal of deck pans After cleaning or servicing in tub area return deck pans to case and return power to case Refrigeration Line Route...

Page 17: ...ub area Illustration below reflects dual evaporator fan 48 60 and 72 units after removal of deck pans After cleaning or servicing in tub area return deck pans to case and return power to case Refriger...

Page 18: ...ee TROUBLESHOOTING TO BE PERFORMED BY STORE PERSONNEL section in manual if LED lights malfunction 9 Thermometer Function Placement Separate thermometers are located in both upper and lower sections of...

Page 19: ...ach door up toward the top of the case pivot the bottom of the door out Return doors to case in reverse order they were removed 11 Rear Perforated Plenum Control Acrylic perforated plenums are used on...

Page 20: ...Coil Hot Gas Loop Condensate Pan Sight Glass Compressor 11 Condenser Package Self Contained Units Assembly disassembly and servicing to be performed by licensed refrigeration contractor Condensate Pac...

Page 21: ...roduct must be kept 1 from upper shelves and or upper UV bonded glass to enhance free airflow Cool air must flow over and around product to return air grille at case front Caution Do not impede air di...

Page 22: ...Consideration Upper section airflow diffuses at rear with return airflow grille at front Do not block air diffuser grille or return air grille Product must be kept 1 from upper shelves and or upper gl...

Page 23: ...remove from case no screw removal required and use a rag or soft bristled brush to wipe off excess dust particles from filter Run in normal dishwasher cycle Remove from dishwasher Dry with soft cloth...

Page 24: ...low instructions as to proper dilution safety precautions and scrubbing method If electric coil overflow evaporator pan is dirty clean it and in same manner while cleaning rest of condenser package Af...

Page 25: ...Remove the Clean Sweep rail Wash rails brushes in hot water and mild soap solution If brushes are worn they must be replaced Call Technical Service Department to replace Toll Free number is listed at...

Page 26: ...olding Proper Temperature If a large amount of warm product was added to the case it will take time for the temperature to adjust Product must be pre chilled before placing in case Check that the case...

Page 27: ...no gap See illustrations below left Power may not be reaching the case Contact store management to have trained service provider perform troubleshooting Troubleshooting to be performed by trained serv...

Page 28: ...rain into Swap out regularly until case has completely drained When power to case is restored condensate pan should function properly and water will no longer overflow onto flooring Check that the dra...

Page 29: ...hat the fan shroud is properly secured Fans Are Not Working Check that the MAIN power switch is on Check that fans are plugged in at the fan shroud Check for foreign material obstructing fan performan...

Page 30: ...perature changes during defrost mode but will return to normal Fourth LED will indicate defrost cycle in progress Check that case is not in sun or near a heat or air conditioning vent If case is locat...

Page 31: ...s Not Operating Check that the utility power is on Check that the MAIN power switch is on Check the circuit breaker box for tripped circuits Condensing Unit Is Not Operating Check that the power is tu...

Page 32: ...system Check that liquid line filter dryer is not plugged Check that close offs are intact around condensing coil and that air is not recirculating Check that store ambient temperature isn t above max...

Page 33: ...e is no air recirculation around evaporator coil Check that evaporator coil is not iced up High Suction Pressure Check for refrigerant overcharge Check that compressor reed valves aren t bad Look for...

Page 34: ...I 49441 Phone 231 798 8888 Fax 231 798 4960 www structuralconcepts com 34 SERIAL LABEL LOCATION INFORMATION LISTED TECH INFO SERVICE Serial Label Location Information Listed Technical Information Serv...

Page 35: ...ing made will resume 3 If the instrument is switched off before pressing the Prg key all modifications to parameters will be lost Set Set aux Prg mute def Prg mute Set Set def Set aux aux def Set Prg...

Page 36: ...alarms reset temp monitoring Summary Table of Alarm and Signals Display Buzzer and Relay Structural Concepts Corp 888 E Porter Rd Muskegon MI 49441 Ph 231 798 8888 Fax 231 798 0393 www structuralconc...

Page 37: ...F 50 200 dP1 Maximum defrost duration evaporator min F 1 250 d6 Display on hold during defrost C 0 2 dd Dripping time after defrost min F 0 15 d 1 Display of defrost probe 1 C F F Structural Concepts...

Page 38: ...onable attorney fees and costs Remedies of SCC SCC s rights and remedies shall be cumulative and may be exercised from time to time In a proceeding or action relating to the breach of this Agreement b...