Driving
Braking
Flyback diodes
IGBT-modules
P
driving
[kW]
I
eff/phase
max. [A]
P
braking
[kW]
I
eff/phase
max. [A]
Device type:
RFE B2/D2
100%
1 min in
10 min
100%
1 min in
10 min
100%
1 min in 10
min
100%
1 min in 10
min
30-500-50-230-A
30
45
35
52
18
30
21
35
45-500-50-230-A
45
70
52
81
28
40
32
46
60-500-50-230-A
60
90
69
104
38
55
44
64
80-500-50-230-A
80
120
92
139
50
70
58
81
100-500-50-230-A
100
150
115
173
70
100
81
115
125-500-50-230-A
125
190
144
220
100
150
115
173
150-500-50-230-A
150
225
173
260
140
200
161
230
250-500-50-230-A
200
300
230
346
180
240
208
277
285-500-50-230-A
250
375
289
433
220
300
254
346
30-500-50-230-A
285
428
329
494
250
340
289
392
Table 3.4.2.3:
All values refer to a mains voltage of 500V
1
Note!
Like the input of a controller the input of the REVCON
-feed- and feedback unit is not protected
for overload. Therefore it is necessary to pay attention not to exceed the maximum input current
of the REVCON
unit when designing the plant. If the maximum input current of the controller
exceeds this value nevertheless, the motor current limit of the controller must be adjusted on the
maximum REVCON value. In any case it is important to calculate with the overload factor of the
controller.