background image

 

DISINFECTION SYSTEM (OPTION) 

 
 

    

 

 
 

COMPOSITION  

 
The bath is equipped with an automatic system to determine the quantity of disinfectant. 
 
The disinfection system includes :  
 

- 1x 2 litres tank receiving the disinfectant product. 
- 1X plunger with calibrated tube, located in the tank, and connected by a flexible going through the top of the 
   venturi (white plastic part). 

 

- 1 disinfection shower. 

 

MANUAL DISINFECTION 

 
Disinfection has to be made after cleaning the tub. 
Use the disinfection shower located on the right of the control panel and sprinkle the tub. 
 

Do not use the disinfection shower on the patient. 

 

Wait in order to respect the action time prescribed in accordance with the disinfectant used. 

 
Rinse with the cleaning shower.  
The bathtub is now ready to another bath. 
 

ADDITION OF DISINFECTION 

 
Dilution :  

 
The mixing of water and disinfectant inside the disinfection shower is made in 2 stages : 

 
First : 

Manual dilution inside the tank. 
 

Second : 

The suction device (venturi) ensures a dosage of 10% of the aspirated product from the tank. 
 

Exemple : 

 
The disinfectant BFR 4.0 must be used with a final dilution of 0,4%. 

 
1)

 Manual dilution inside the tank at 4%, that is 80ml of BFR 4.0 for 1920ml of water. 

2)

 Complementary dilution of 10% ensured with 

cold water

 by the suction device (venturi). 

 

 

16/20 

Summary of Contents for 7800.00

Page 1: ...EN Instruction manual ELECTRIC Hi Lo Bathtub Cocoon 7800 00 7801 00 7802 00 7803 00...

Page 2: ...OTHERAPY OPTION 13 AUDIO SPA OPTION 13 AUTOMATIC STOP FILLING 1 LEVEL FOR 7801 00 7803 00 14 AUTOMATIC STOP FILLING 1 LEVEL FOR POUR 7800 00 7802 00 14 AUTOMATIC STOP FILLING 2 LEVELS 15 DISINFECTION...

Page 3: ...ters up down buttons chromotherapy button air whirlpool controls automatic stop filling buttons flow intensity valve for cleaning shower handset Aromatherapy Cleaning shower handset Plug control overf...

Page 4: ...DIMENSIONS 3 20...

Page 5: ...er OPTIONS REF 7800 10 Disinfection shower handset with trigger flow adjustment suction device of the disinfectant product with stop valve 2 litres tank secured door with lock with key REF 7800 20 12...

Page 6: ...stop filling 1 level on modes 7801 00 7803 00 Compatible with chair and stretcher lifts 40mm draining plug with siphon PERFORMS Max patient weight 160kg Max weight water patient 320kg Weight of the Co...

Page 7: ...water for a better effectiveness of the disinfectant product A compressor assures whirlpool in option That is injection of air under pressure with adjustable flow through 12 nozzles equipped with anti...

Page 8: ...b DO NOT adjust the water temperature over 43 C in the presence of patient DO NOT use any electrical appliances near the tub DO NOT use any electrical appliances hair dryer or electric razor while in...

Page 9: ...GH LOW FUNCTIONS In order to change the height of the tub use the buttons located on the control panel PLUG OPERATION Turn the button in a clockwise direction to close the drain plug and counter clock...

Page 10: ...ning shower after 30 seconds Check water temperature before each submersion If the bathtub is equipped with the option automatic stop of filling it is advised to carry out a test of the sensor before...

Page 11: ...by the valve located under the mixer Filling and stop filling is made by turning the valve button CLEANING SHOWER HANDSET Select a temperature by adjusting the thermostatic It is possible to regulate...

Page 12: ...do not forget to turn off the 1 4 turn stopcock a shower under pressure being much more fragile AIR WHIRLPOOL OPTION That is injection of air under pressure with adjustable flow through 12 nozzles equ...

Page 13: ...matherapy system on via the circular control panel Once up to temperature the heated air infuses with the aroma oil and releases its fragrance into the water via the diffuser jets positioned in the bo...

Page 14: ...s of two loudspeakers a waterproof amplifier a MP3 player and a control panel including the commands One Off and volume as well as an embedded box with removable panel allowing to receive and to conne...

Page 15: ...automatically The sensor issues a magnetic field that is modified when water reaches it CONTROL PROCESS OF THE CAPACITIVE SENSORS 1 Start filling the bath 2 With the cleaning shower spray the inside...

Page 16: ...tton n 2 To activate the water level n 2 push on the button n 2 and deactivate the button n 1 In case none of the buttons is activated the automatic stop filling does not work and the bathtub will fil...

Page 17: ...e tub Do not use the disinfection shower on the patient Wait in order to respect the action time prescribed in accordance with the disinfectant used Rinse with the cleaning shower The bathtub is now r...

Page 18: ...nce per week A regular cleaning of these 2 filters is imperative in order to reduce the limestone deposits in the pipes of the bathtub A bad maintenance of these filters generates times of long fillin...

Page 19: ...oning of a whirlpool s nozzle Air is lown through the nozzle and discharged under the chromed air jet cap There is a risk of heating the air jet cap is the nozzles are not regularly cleaned Layers of...

Page 20: ...h should be retained by the person s responsible for the servicing maintenance of the bathtub The date when corrective actions are taken in response to noted observations should also be noted in the l...

Page 21: ...MAINTENANCE FORM LOGBOOK Agent name and signature Corrections Observations Safety parts Control date 20 20...

Page 22: ...ulle Tel 33 05 46 42 04 16 Fax 33 05 46 43 06 38 www groupe reval com UNITED KINGDOM Reval Continuing Care Limited Unit 17 Brynmenyn Busines Centre St Theodore s Way Brynmenyn CF32 9TZ BRIDGEND WALES...

Reviews: