require an “Enable” icon button to be held for 3 seconds to confirm
AGS activation�
Touch the “Inverter” icon to power the inverter on or off� A blue
“Inverter” icon indicates the unit is on� A grey “Inverter” icon indicates
the unit is off� Keep in mind that the inverter will quickly deplete the
house battery bank if the coach is not connected to shore power or
another power source such as the chassis’ 3�0 diesel engine alternator
or the optional Onan LP generator� See the INVERTER section below
for further instructions on the operation of the inverter�
Your coach may have an “Energy Management” section on the
“Electrical” page. The Energy Management System (EMS) will activate
when the AC Power Management option is selected� EMS does not
operate when connected to shore power, or whenever the generator is
running�
Once activated, the EMS loads are shed according to the
following priority order:
1. Dometic AirCon
- This is present if no ProAir options are
enabled, or if ProAir Clutch is enabled without ProAir Variable;
2. Convection Stove
- EMS will try to turn on this load (OFF ch�
10) as soon as the system starts if there is power. This will
turn ON ch� 10 if the load is SHEDDING or OFF� There is no
on-screen control for the induction cooktop; and,
3.
Water Heater
- This will turn ON ch� 15 if the load is SHED-
DING or OFF� It will also turn the Water Heater icon button
color to yellow if it is shedding with ch 15�
ON�
Tap the icon button to Enable or Disable AGS� A warning message
will require action to Enable� Two “Trigger Options” are available to
automatically start the generator using specified voltage settings (Low
Volts) or when A/C or Heat starts (HVAC). Select one or both
triggers� If no triggers are selected, AGS will not run� Disable HVAC
Load while you are connected to shore power to prevent the
generator from starting�
Set the trigger options as follows:
Start at Volts
- The generator will start when the voltage drops to
this set point depending on the “Time at Start Volts” setting below�
(Available range is 10.5v – 12.5v);
Time at Start Volts
- The generator will start when the voltage drops
to the Start at Voltage for this specific amount of time. (Available range
is 5 seconds – 1 minute);
Stop at Volts
- The generator will shut off when the voltage reaches
this set point depending on “Time at Stop Volts” setting below�
(Available range is 13.2v – 14.5v); and,
Time at Stop Volts
- The amount of time required for the voltage to
remain at “Stop at Volts” level before the generator shuts off�
(Available range is 5min – 120min).
Summary of Contents for Midwest Automotive Design American Coach Patriot 2022
Page 1: ...PATRIOT O W N E R S M A N U A L...
Page 2: ...574 522 4878 midwestautomotivedesigns com 1826 Leer Drive Elkhart Indiana 46514...
Page 3: ...Table of Contents...
Page 7: ...SECTION 1 Introduction...
Page 10: ......
Page 11: ...SECTION 2 Limited Warranty...
Page 15: ...SECTION 3 General Information...
Page 18: ......
Page 19: ...SECTION 4 Safety...
Page 36: ......
Page 37: ...SECTION 5 Before You Go...
Page 50: ......
Page 51: ...SECTION 6 Exterior Features and Care...
Page 65: ...SECTION 7 Interior Features Functions and Care...
Page 77: ...SECTION 8 Plumbing and Sanitation Systems...
Page 90: ......
Page 91: ...SECTION 9 Electrical Systems...
Page 108: ......
Page 109: ...SECTION 10 Appliances...
Page 119: ...SECTION 11 Infotainment System...
Page 127: ...SECTION 12 Winterization and Storage...
Page 135: ...SECTION 13 Maintenance...
Page 156: ......
Page 157: ...SECTION 14 Schematics and Illustrations...
Page 172: ......
Page 173: ...SECTION 15 Index...
Page 176: ......
Page 177: ...574 522 4878 midwestautomotivedesigns com 1826 Leer Drive Elkhart Indiana 46514...