RETTIG LANGILA Series Instructions For Fitting And Use Download Page 6

66  | M16MI364 - A04 - 04/18

INSTALLATION AND MAINTENANCE OF YOUR RADIATOR

EN

STANDARDS        Double Insulation Category  II 

 

 - IK09 - 

 - IP44* 

These radiators comply with standards EN 60.335-1, 60.335-2-30. These 
appliances benefit from a double insulation on the electrical parts - 
category II are protected against water ejections (IP44*) and benefit from 
mechanical shock resistance (IK09). They also comply with the European 
directive 2004/108/EC (EC marking on all appliances).

These appliances are not made to be used by people (including children) 
with limited physical, sensorial or mental capabilities or people devoid 
of experience or knowledge unless they have been able to benefit from a 
person responsible for their safety or from prior supervision or 
instructions concerning the use of the appliance.  It is advisable to super-
vise children to ensure they do not play with the appliance.

LOCATION

To fully enjoy your appliance and for your greatest convenience, please 
consider the following recommendations:
•  The lower part of the thermostat must be at least 150 mm from the  
  floor.
•  The appliance must not be installed less than 40 mm from a wall nor  
  below a socket.
•  Any shelf put above the radiator must be at least 150 mm from it.
•  It is recommended to install the radiator near locations with strong  
  heat loss (windows…), and to use fixing screws adapted to the nature  
  of your wall and to the weight of the appliance.
This appliance must never be installed with its thermostat in a high 
position.  The thermostat must not rest on the floor.  Simply use wedges 
when installing to protect it.

CONNECTION

The technical features of your appliance are indicated on its nameplate 
situated on the radiator, close to the thermostat.  Please take note of this 
before any after-sales intervention.
Power is supplied by 230-240 V~/50Hz or by 400 V~/50Hz. An all-pole 
switch is compulsory. The separation distance between contacts must be 
at least 3 mm. Connect the cable of the terminal board of the cable 
adaptor by following the following instructions:

230-240V

•  Brown wire = Phase (Pin 1), 
•  Grey or Blue wire = Neutral (Pin 2), 
•  Black wire = Night reduction signal or external clock (Pin 3, not to  
  earth). The black cable provides drop in temperature if it is connected  
  to Neutral.  It must never be connected to the earth and must be insu 
  lated from any contact if not used.

400V

•  Brown wire = Phase 1 (Pin 1), 
•  Grey or Blue wire = Phase 2 (Pin 2), 
•  Black wire = Night reduction signal or external clock (Pin 3, not to  
  earth). The black cable provides drop in temperature if it is connected  
  to Neutral.  It must never be connected to the earth and must be insu 
  lated from any contact if not used.

The power cable originally provided must be connected to the network 
by a connection box that should be placed behind the appliance, free 
from a wall socket and situated at least 250 mm from the floor (kitchen 
& bathroom).

For Yali GV, Sanbe, Langila: The grey connector may, if so desired, be 
covered by the supplied protection box, see pictures.

If the power cable is damaged, it must be replaced by a specific cable.  
This cable must be replaced by the manufacturer, its after-sales service or 
people with similar qualifications to avoid any hazard.

SPECIAL INSTALLATION RULES CONCERNING BATHROOMS

In addition to the rules stipulated 
in these instructions, the 
appliances must be installed 
in accordance with applicable 
standards and good engineering 
practice.
This appliance is IP44*. It is there-
fore protected against water 
ejections and can be installed in 
volumes 2 and 3, provided that 
the thermostat cannot be reached 
by a person using the bath or 
shower (i.e. the thermostat must 
be installed in volume 3).  It must 
not be connected to a ground 
terminal.

•  A ground fault circuit interrupter of 30mA maximum is compulsory  
  for bath rooms or shower rooms.
•  Switches and controlling devices can be placed by ensuring they can 
  not be reached by anybody using the bath or shower.

USE

WARNING - In order to avoid overheating, do not cover the 
heater.“Do not cover” means that the radiator must not be 
used for drying clothes, for example, by placing them directly 
on the radiator.

For the working of the electronic control refer to the instructions pro-
vided with the RF transmitter. 

MAINTENANCE ADVICE

Maintenance must be carried out on a turned off radiator. Therefore 
ensure the appliance is disconnected from the electric network before 
doing any manintenance.  To ensure the longevity of your radiator, we 
recommend applying the following advice:
•  Use a dry cloth (without solvent) for the control unit,
•  Use warm soapy water to look after the radiator's external walls (no  
  abrasive or corrosive product).

This heating appliance is filled with a precise quantity of coolant, special 
oil or glycol water depending on the appliance.  Repairs requiring the 
tank to be opened must only be carried out by the manufacturer or its 
after-sales service that must be contacted in the event of an oil or glycol 
water leak.  This fluid, specially developed for this use requires no special 
maintenance. 

When scrapping the heater, follow the regulations concerning the 
disposal of oil.

ENVIRONMENTAL REGULATIONS

ROHS: Complies with directive 2002/95/EC
DEEE: Complies with directive 2002/96/EC

Handling electrical and electronic appliances at the end of their shelf life 

This symbol indicates that this product must not be processed 
with household waste.  It must be taken to a suitable collection 
point that will look after recycling it.  By discarding this product 
appropriately, you will help prevent any possible negative 

consequences for the environment and human health.  When the 
heating appliance is discarded, respect the regulations concerning the 
disposal of the oil.

*) IP44  when the water protection cover (that is supplied) is mounted. 
If the product is installed only with the connection box the product is IP21

WARRANTY

The warranty is valid for 10 years except for electrical compo-
nents which is valid for 2 years. In the event of any problems or 
repairs, please contact your supplier.

Summary of Contents for LANGILA Series

Page 1: ...D FILLED ELECTRIC RADIATOR WITH ELECTRONIC THERMOSTAT V TSKEFYLLD ELRADIATOR MED ELEKTRONISK TERMOSTAT LIQUID FILLED ELECTRIC RADIATOR WITH ELECTRONIC THERMOSTAT LIQUID FILLED ELECTRIC RADIATOR WITH E...

Page 2: ...e use of the appliance and if the potential risks have been understood Children shouldn t approach the appliance nor climb on it Usercleaningandmaintenancemust not bedonebychildrenwithout supervision...

Page 3: ...om de vervakas eller f r instruktioner om hur man anv nder elradiatorn p ett s kert s tt och f rst r vilka risker som finns Barn f r inte leka med elradiatorn Reng ring och annat anv ndar underh ll f...

Page 4: ...vis de er under passende tilsyn eller hvis de har oppl ring i sikker bruk av apparatet og har forst tt de potensielle farene Barn m ikke leke med h ndklestativet og heller ikke klatre p det Rengj ring...

Page 5: ...ja tiedot ovat puutteelliset jos heit valvotaan asianmukaisesti tai jos heille on annettu laitteen turvallista k ytt koskevat ohjeet ja jos he ymm rt v t mahdolliset vaarat Lapset eiv t saa leikki lai...

Page 6: ...r may if so desired be covered by the supplied protection box see pictures If the power cable is damaged it must be replaced by a specific cable This cable must be replaced by the manufacturer its aft...

Page 7: ...se bilder Om elkabeln skadas ska den ers ttas med en ny specialkabel F r att undvika alla risker f r detta endast utf ras av tillverkaren dennes garantiavdelning eller liknande kvalificerade personer...

Page 8: ...lig dekkes over av den medf lgende beskyttelsesboksen Se bildene nedenfor Hvis str mkabelen er skadet m den erstattes med en bestemt kabel Denne m byttes av produsenten dennes servicepersonale eller p...

Page 9: ...n olla maadoitukseen ja sen tulisi olla t ysin eristetty jos sit ei k ytet KYLPYHUONEASENNUKSIA KOSKEVAT ERITYISS NN T N iss ohjeissa annettujen s nt jen noudattamisen lis ksi laitteet on asennettava...

Page 10: ...alternativ kan markeras Rumstemperaturreglering med n rvarodetektering Ja Rumstemperaturreglering med detektering av ppna f nster Ja Med m jlighet till fj rrstyrning Ja Yhteystiedot RETTIG Heating Gro...

Page 11: ...detektering av ppna f nster Ja Med m jlighet till fj rrstyrning Ja Yhteystiedot RETTIG Heating Group France Immeuble Rimbaud 22 Avenue des Nations 93420 VILLEPINTE Kontaktuppgifter RETTIG Heating Gro...

Page 12: ...alternativ kan markeras Rumstemperaturreglering med n rvarodetektering Ja Rumstemperaturreglering med detektering av ppna f nster Ja Med m jlighet till fj rrstyrning Ja Yhteystiedot RETTIG Heating Gro...

Page 13: ...detektering av ppna f nster Ja Med m jlighet till fj rrstyrning Ja Yhteystiedot RETTIG Heating Group France Immeuble Rimbaud 22 Avenue des Nations 93420 VILLEPINTE Kontaktuppgifter RETTIG Heating Gro...

Page 14: ...14 14 M16MI364 A04 04 18...

Page 15: ...15 M16MI364 A04 04 18 15 INFORMATION product reference product model options purchase date supplier supplier phone number invoice n...

Page 16: ...w lviprodukter se NORGE LVI Tlf 67 58 33 11 Faks 67 58 33 77 info lviprodukter no www lviprodukter no SUOMI Myyntikonttori LVI Kauppakartanonkatu 7A 62 00930 Helsinki Puh 09 7269 1040 Fax 09 7269 1060...

Reviews: