FLA
Full Load Amps
H-WIRE
Hard Wired
HA
Heater Amps
Hp
Horse Power
Htr #
Heater Option Number (see Figure 1)
IFM
Indoor Fan Motor
LRA
Locked Rotor Amps
Max
Maximum
MCA
Maximum Circuit Ampacity
Min
Minimum
MOCP
Maximum Over current Protection Device
Amps
(HACR-type breakers or time-delay fuses)
OFM
Outdoor Fan Motor
RLA
Rated Load Amps
TCA
Total Cooling Amps
THA
Total Heating Amps
Volt
Voltage
W
Watts
Table 4 Legend For Electrical Specifications
ELECTRICAL SPECIFICATIONS
Table 5 RQTH 18 Electrical Specifications
Power
Supply
Volt 1–60
Compressor Indoor Fan
Motor
Outdoor
Fan Motor
Electric Heat
Unit Electrical Ratings
Volt
Min
RLA
LRA
FLA
Hp
FLA
Hp Htr # Volt
W
HA
TCA THA MCA MOCP H-Wire
208/
230V
197
7.3
48
1.3
0.25
0.5
0.5
0.125
0.125
5
208
4089 19.7
9.6
21.0 26.2
30
H-Wire
230
5000 21.7
23.0 28.8
7
280
5725 27.5
28.8 36.0
40
H-Wire
230
7000 30.4
31.7 39.7
Table 6 RQTH 24 Electrical Specifications
Power
Supply
Volt —
1–60
Compressor
Indoor
Fan
Motor
Outdoor
Fan Motor
Electric Heat
Unit Electrical Ratings
Volt
Min
RLA
LRA
FLA
Hp
FLA
Hp
Htr
#
Volt
W
HA
TCA THA MCA MOCP H-Wire
208/
230V 197
10
58.3
1.3
0.25 0.5
0.5
0.125
0.125
7
208
5725 27.5
12.3
28.8 36.0
40
H-Wire
230
7000 30.4
31.7 39.7
10
208
8178 39.3
40.6 50.8
60
230 10,000 43.5
44.8 28.4
20
Made in USA