Resource Data Management Mercury PR0018 User Manual Download Page 13

                                                                                        

 

 

 

  

Revision 2.1D 

 

Page 13 of 14 

 

 

www.resourcedm.com 

Mercury Switch User Guide

 

 

Warning 

 
 
 
 
 
 

Please Note 

The specifications of the product detailed on this 
Set-Up  Guide  may change without notice. RDM 
Ltd. shall not be liable for errors or for incidental 
or consequential damages, directly and indirectly, 
in connection with the furnishing, performance or 
misuse of this product or document.

 

Ensure that all power is 
switched off before   
installing or maintaining 
this product 

Network Alarms 

 

The table below shows the text and associated type number that is sent to the system "front end". The type number is normally used to 
provide different alarm actions. 
 

Alarm text 

Type # (Index) 

 

 

Transducer Fault 

High Pressure Alarm 

MOP Alarm 

Remote Pressure 

 

Setup via Webpages  

 
The Mercury Switch can be configured by navigating to the Mercury Switch WebPages. This can be achieved by using the Controller Info 
page in the Data Manager/Data Director. Find the IP address assigned to the Mercury Switch in question from the list. Now connect a 
laptop onto the IP network on which the Mercury Switch is connected. Using a web browser navigate to the IP address of the Mercury 
Switch. The homepage of the Mercury Switch is shown below: - 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 

 
Click on “Configure” to set the type: - 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Then click “Type” 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Use the drop-down selec

tion to select the type required and then click “Set Type”. Parameters can be changed using the connection as 

illustrated above or through the normal Data Manager/Director change parameter routes or through the display if fitted (PR0445). 
 
 

Summary of Contents for Mercury PR0018

Page 1: ...ercury Switch User Guide Resource Data Management Ltd 80 Johnstone Avenue Hillington Industrial Estate Glasgow Scotland G52 4NZ UK 44 0 141 810 2828 Switchboard support resourcedm com Technical Suppor...

Page 2: ...Setup via Display 5 Recommended set up method 6 Set View Type 6 Set View Parameters This can also be achieved at the network front end 6 ID 6 Network Configuration 6 IP L Local IP Address 7 IP r IP Ad...

Page 3: ...s As well as the Switch function there is the option for Island EEV control This control can be achieved by using a transducer connected to the Mercury Switch 4 20mA input or from a remote Suction pre...

Page 4: ...elf configuring Connection to a Data Manager Director Use a standard CAT5 patch lead and connect the Data Manager or Data Director to one of the 3 10 Base T ports 10 100 Base T connectors The three 10...

Page 5: ...splay The display fits a standard UK single socket pattress Enter Button Button used to enter confirm values after a change Up Button When in the software menu the up button is used to scroll up throu...

Page 6: ...press Enter again to save the value The parameter list number will be displayed again Two other options are present in the parameter menu dFLt and ESC Selecting ESC will exit setup mode Selecting dFLt...

Page 7: ...ed by the DHCP server To configure the Mercury Switch for IP r set the two rotary switches to give each controller a unique identifier The controller should then be connected to the network 2 nEt From...

Page 8: ...5 0 to 7 2 0 1 Bar Psi 0 1 P 17 Evap 7 offset 0 0 to 0 5 0 to 7 2 0 1 Bar Psi 0 1 P 18 Evap 8 offset 0 0 to 0 5 0 to 7 2 0 1 Bar Psi 0 1 P 19 Evap 9 offset 0 0 to 0 5 0 to 7 2 0 1 Bar Psi 0 1 P 20 Ev...

Page 9: ...educed to a predetermined percentage A MOP alarm is also created See MOP P 41 MOP Diff When the pressure reduces below this value valves on controllers connected to the Switch will recover to their no...

Page 10: ...te 1 Temperature 49 0 to 60 56 2 to 140 0 o C o F O 34 Remote 2 Temperature 49 0 to 60 56 2 to 140 0 o C o F O 35 Remote 3 Temperature 49 0 to 60 56 2 to 140 0 o C o F EEV Control Operation Product PR...

Page 11: ...ury Switch Or the remote Mercury Plant Controller The Mercury Case controllers require to have P17 Evaporator control set to 1 Remote for this feature to function Mercury Switch Type There are 4 types...

Page 12: ...et to Remote and the Data Manager GP timer channel directed to the Mercury Switch is in the on period the humidity control will operate as described above During the Data Manager GP timer channel off...

Page 13: ...to the Mercury Switch WebPages This can be achieved by using the Controller Info page in the Data Manager Data Director Find the IP address assigned to the Mercury Switch in question from the list No...

Page 14: ...in the UK manufactured in Taiwan Ventilation There is no requirement for forced cooling ventilation Class 2 Insulation No protective Earth is required and none should be fitted The host equipment must...