background image

RE926X_Flexible Bus WiFi Communicator

 

Page 

1

 of 

8

 

10-Mar-15 

24-hour Tech Support: (715)808-0164 

www.ResolutionProducts.com

 

 

 

A/Rx

CLK
B/Tx

DATA
GND
+12V

Honeywell

Vista 20P or 15P

DATA OUT

7

DATA IN

6

AUX +

5

AUX -

4

Green

Y ellow

Red

Black

RE926X

WiFi

Module

 

 

 

 

RE926X Flexible Bus WiFi Communicator 

 

Features 

 

 

Connects panels to local WiFi Network 

 

Compatible with: 

o

 

Honeywell Vista® 15P and 20P 

o

 

DSC PowerSeries®

 

o

 

Future: UTC NX, UTC Concord

 

 

Enables: 

o

 

Alarm Reporting 

o

 

Interactive Control Functions 

o

 

Ethernet data reliability 

o

 

Z-Wave Communicator included 

 

Key Instructions

 

 

The same unit works for Vista & DSC PowerSeries 
[Future: UTC NX, and UTC Concord].   

 

Selectable switch determines panel compatibility. 

 

DO NOT MOUNT INSIDE METAL CAN – there are radios on the boards that 
need to be in free-air to communicate. 

 

Communicator must be connected to a 12V nominal power supply with 
battery backup, such as the control panel's aux power output. 

 

RE926X communicates with the Vista 15P/20P via AUI device 2.  
Enable AUI 2 in the Vista.

 

Wiring Instructions  

NOTE:  

Some programming must be done PRIOR to connection 

Maximum cable lengths shown in the table below, this assumes the communicator is 
the only device attached to the cable. If multiple devices share the same cable, the 
maximum cable length must be derated accordingly.

 

 

Wire Size (AWG) 

Maximum cable length to Control Panel 

18 

600 

22 

250 

24 

150 

 

 

DSC 

PowerSeries

Y EL

GRN

AUX - BLK

AUX + RED

Green

Y ellow

Red

Black

RE926X

WiFi

Module

A/Rx

CLK
B/Tx

DATA
GND
+12V

RE926X_Flexible Bus WiFi Communicator

 

Page 

2

 of 

8

 

10-Mar-15 

24-hour Tech Support: (715)808-0164 

www.ResolutionProducts.com

 

 

Vista 20P and Vista 15P Programming:

 

Compatible Honeywell Panels: 

Vista 20P 

(version 3.0 or later) (controls partition 1 only) 

Vista 15P 

(version 3.0 or later) 

1)

 

Refer to server setup instructions and set up the account on the Dealer 
Portal. 

2)

 

Be sure to add a contact that uses the system MASTER CODE to the account before 
connecting the module. This will ensure the module can properly communicate 
with and configure required system settings. 

3)

 

Disarm the system (all partitions). 

4)

 

The RE926X automatically communicates with the Vista using AUI device 2.  

The panel is probably defaulted to this.  If not, enable AUI 2 in the *189 field.   

5)

 

Power down the Vista system. 

6)

 

Set RE926X panel selector switch to Honeywell:   DSC   CDX    HW    UTC 

7)

 

Connect the Vista and RE926X as shown in the Wiring Instructions above. 

8)

 

Apply power to the Vista 15P/20P system.   

The Vista control panel will begin automatic configuration.   
Can move to Step 8 during this…  

9)

 

WiFi Protected Setup connection to Router (see Operation – WiFi Protected 
Setup connection to Router) 

10)

 

The module will automatically connect itself to the server, and then enable 
the following settings automatically: 

IP/GSM device (*29) 
Communicate to IP/GSM device first (*55) 
Test Report off (*64) 
Opening Report (*65) 
Closing reports (*66) 
Alarm cancel report (*68) 
AC Power restoral report (*73) 
Low Battery restoral report (*74) 
Phone Monitor off (*92) 

11)

 

 Finally, the keypad(s) should display "DISARMED Ready to Arm". 

12)

 

 Installation is complete.

 

Reviews: